84
Name
Data length
[byte]
Description
Remarks
Center
position X
8
“-999.999”–“+999.999” [mm]
The center coordinate of arc is indicated.
Center
position Y
8
Radius
8
“+000.000”–“+999.999” [mm]
Radius of
line interval
7
Model type*
Setting range [mm]
LP-Sxx0(W)
“000.000”–“090.000”
LP-Sxx5(W)
“000.000”–“160.000”
LP-Sxx2
“000.000”–“055.000”
LP-Mxx0/LP-Zxx0 “000.000”–“120.000”
LP-Mxx5
“000.000”–“220.000”
LP-Mxx6/LP-Zxx6 “000.000”–“330.000”
The difference of radius from the center
position of marking position to the next line
is indicated when the character string is
marked over two or more lines.
Start angle
7
“-180.00”–“+180.00” [°]
The angle from the positive (+) side of
X coordinate with counter-clockwise at
the first character in character string for
marking is indicated.
Angle of
character
interval
7
“-180.00”–“+180.00” [°]
The angle between the center of character
and the center of next character is
indicated.
Font No.
2
Char. Font “01”–“10”
The number corresponding to the 10 fonts
previously registered is indicated.
Bold line
width
5
Model type*
Setting range [mm]
LP-Sxx0(W)/LP-Sxx2/
LP-Mxx0/LP-Zxx0
“0.000”–“2.000”
LP-Sxx5(W)/LP-Mxx5/
LP-Mxx6/LP-Zxx6
“0.000”–“4.000”
Laser power
correction
3
“000”–“999” [%]
•
The correction ratio is calculated using
the value set at the laser condition as
100%.
•
With LP-SxxxW type, nothing should be
input in Laser Pulse Cycle Correction.
Scan speed
correction
3
“001”–“999” [%]
(Laser pulse
cycle cor.)
(3)
“001”–“999” [%]
* For the detail of the model type, refer to “Target laser marker” (P.4).
Reference
•
At marking of bold characters, set the values so ratio of character height to character width be within 1/10 to 10.
•
Set the Bold line width to 1/2 or less of the character height or the character width, whichever is smaller.
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...