3-5-4 Guide laser
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
T1
SHUTTER
OUT *1
READY OUT
GUIDE IN
SELECT 0 to 2 IN
SHUTTER B IN
SHUTTER A IN
(Open)
(Close)
*1 : Shutter output signal has around 200ms to max. 1 sec. delay from each input signal for the shutter open / close
operation time.
The operation behavior of Shutter 2 output on LP-Mxxx/Mxxx-LS1 type is the same as Shutter output.
Item
Time
Remarks
T1
0.5 ms or more
After a lapse of 0.5ms or more from specifying SELECT 0 IN to SELECT 2 IN, turn on
GUIDE IN.
Select the guide laser radiation details by the select input. Turn on the guide laser radiation input by entering the SELECT 0
to 2 input as shown in the below table.
Radiation details
SELECT 0
SELECT 1
SELECT 2
Dual pointer
OFF
OFF
OFF
Marking contents
ON
OFF
OFF
Marking field
OFF
ON
OFF
Work image
ON
ON
OFF
ンㄆㄇㄆㄓㄆㄏㄆ
• You can use the guide laser regardless of the input status of LASER STOP 1 in I/O terminal, but you cannot use the
guide laser while LASER STOP 2 is opened.
• For -LS1 type, you can use the guide laser even when the interlock connector is opened under the remote mode. For
other models, guide laser cannot be used when the interlock connector is open under the remote control mode.
• Guide indication by I/O guide laser input is unavailable when the No. 2 DIP switch on the back surface of controller is
turned to ON.
• If inputting GUIDE IN repeatedly, turn ON GUIDE IN at intervals of more than 500 msec.
ME-LPM-SSM-10
Summary of Contents for LP-M Series
Page 16: ...16 MEMO ME LPM SSM 10...
Page 27: ...27 Chapter 1 Specification ME LPM SSM 10...
Page 37: ...37 Chapter 2 Preparation ME LPM SSM 10...
Page 69: ...Chapter 3 Connection for External Control ME LPM SSM 10...
Page 128: ...Chapter 4 Maintenance ME LPM SSM 10...
Page 148: ...Troubleshooting ME LPM SSM 10...
Page 169: ...Index ME LPM SSM 10...
Page 172: ...172 MEMO No 9000 0066 34V ME LPM SSM 10...
Page 173: ...No 9000 0066 34V...