129
INPUT ASSIST
With this input assist function, the setting for constant offset within the arbitrary parallel data No. becomes easy one.
1
2
3
4
Description
1
Index Range:
Specifies the target starting parallel data No. and ending parallel data No. for setting.
2
Setting Item:
Specifies the setting item. “
θ
offset”, “X offset”, “Y offset”, “Z offset” (only for LP-M / LP-Z series), and “Laser
Power Cor. (Laser Power Correction)”.
3
Initial Value:
Specifies the setting value to be input to the starting parallel data No. specified in “1 Index Range” above.
4
Step Value:
Specifies the step value. Specify the starting parallel data No. as the initial value, and reflect the setting value for
each parallel data No. by step amount.
Setting Sample
Index Range: 0001 to 0004, Setting Item: X offset, Initial Value: 1.000 mm, Step Value: 1.000 mm
Parallel Data No. 0001
u
X offset:
1.000 mm
Parallel Data No. 0002
u
X offset:
2.000 mm
Parallel Data No. 0003
u
X offset:
3.000 mm
Parallel Data No. 0004
u
X offset:
4.000 mm
ME-LPMSZ-OP-7