167
Setting for QR Code and Data Matrix Code
2
3
1
5
3
4
5
Data Matrix
QR code
Description
1
Version (QR code only):
Specifies the symbol size of QR code and micro QR code.
When “0” is selected, the size is specified to be the minimum automatically. In this case, the symbol size may
change depending on the input code data.
Refer to “QR Code Version and Data Capacity” (P.287) for detail.
Setting Range
QR code model 1 : 0 to 14
QR code model 2 : 0 to 22
Micro QR code : 0 to 4
2
Symbol (Data Matrix code only):
Specifies the symbol size (module unit) of data matrix code. Select “Auto” or “Manual”. When “Auto” is selected, the
size is specified to be the minimum.
Refer to “Symbol Size and Data Capacity” (P.290) for detail.
Square
: 10×10, 12×12, 14×14, 16×16, 18×18, 20×20, 22×22, 24×24, 26×26, 32×32, 36×36, 40×40,
44×44, 48×48, 52×52, 64×64, 72×72, 80×80, 88×88
Rectangle
: 8×18, 8×32, 12×26, 12×36, 16×36, 16×48
3
Mode :
Input mode for the code data. Depending on the mode, available characters vary. Refer to “Code Type and Code
Data” (P.159).
•
For QR code, select the mode from “Number”, “Alpha”, “Binary” or “Kanji”.
•
For Data Matrix code, select the mode from “ASCII” or “Kanji”.
• For GS1 Data Matrix code, data input mode is fixed to binary mode.
4
Err. Cor. (Error Correction) (QR code only):
Specifies the error correction level of QR code.
Select from “L (7%)”, “M (15%)”, “Q (25%)” or “H (30%)”.
5
Module H/W (Module Height/Width) :
Specifies the height and width of module which compose a symbol.
Setting Range
0.001 to 9.999 mm
Reference
• If the size of module is same as or very smaller than that specified at “2-6 Selecting Marking Mode” (P.91), the module
inside the encode area may not be marked uniformly. In this case, enlarge the size of the module or narrow the line.
ME-LPMSZ-OP-7
Summary of Contents for LP-M Series
Page 11: ...1 Basic Operation Procedure ME LPMSZ OP 7 ...
Page 76: ...76 MEMO ME LPMSZ OP 7 ...
Page 77: ...2 Description of Operation Screen ME LPMSZ OP 7 ...
Page 102: ...102 Symbol ME LPMSZ OP 7 ...
Page 255: ...Troubleshooting ME LPMSZ OP 7 ...
Page 276: ...Appendix ME LPMSZ OP 7 ...
Page 304: ...Index ME LPMSZ OP 7 ...
Page 307: ...No 9000 0063 56V ...
Page 308: ... Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 56V ...