189
Marking energy measurement
Notice
•
If the marking energy falls below 1000 mJ or the marking time falls short of 0.4 second, the measurement may be
unstable.
1.
Set the [Laser Power], [Scan Speed] and [Laser Pulse
Cycle] when measuring the marking energy, and then
press [TEST MARKING].
2.
Confirmation dialog box appears.
Press [OK].
The screen returns to the procedure 1 by pressing [Cancel].
WARNING
•
The laser beam radiates. Be sure to use the protective goggle and enclosure
while dealing with the laser.
•
Once starting the test marking, the laser radiation cannot be stopped till the
marking is finished. If the operator needs to stop the laser radiation, use the
interlock system constructed by using the interlock connector on the controller.
Reference
•
For LP-Mxxx-S type, laser can not be emitted without opening the laser gate. After starting the test marking, open the
laser gate by external control signals. Refer to the “Safety / Setup / Maintenance Guide” for detail.
3.
The marking energy measurement result appears.