196
Item
Description
Reference
•
In case of LP-M / LP-Z series, to use the function of Marking to Flying Object in combination with 3D setting, use the
encoder. The marking to flying object without encoder is not available.
4
Encoder Pulse
: Inputs the resolution of encoder provided in the line.
Setting Range
5.00 to 600.00 P/mm
Calculation of encoder pulse number (5.00 to 600.00 P/mm)
Encoder Pulse
=
Pulse number of one
rotation of encoder
÷
Line distance advanced during
one rotation of encoder
×
4 or 2 *
* When using A and B phase: 4
* When using either A or B phase: 2
Reference
•
Up to 100kHz per one phase is possible to be input to the encoder input on the input terminal block.
•
Use only “A” phase (ENC(A)) of the input terminal block input and connect “B” phase (ENC(B)) to input common if
either of these encoders is used.
•
If the setting value for the encoder pulse is too small, the marking quality might be deteriorate. (Depending on the
marking condition, the recommendation setting value for the encoder pulse is 25.00 P/mm or more.)
5
Fly. Obj. Wait.
(Flying Object Wait)
:
Waiting period for marking corresponding to the line speed for flying object marking.
Setting Range
0.00 to 500.00 ms
Adjust the waiting time of the marking for flying object so that the width of the character
string is as shorten as possible shown below when performing the test marking
remaining the setting of the marking for flying object.
Too Narrow
Proper
Too Wide
If the error occurs during the marking to flying object, adjust the following settings.
ERROR
CODE
Description
Setting Position
Scan
Speed
Line
Speed
Flying
Object
Wait
E620
The marking is performed after the work is
moved to outside of marking field.
Shift to moving
direction
Up
Down
Down
E621
The marking is performed before the work is
entered into the marking field.
Shift to opposite
direction of moving
direction
Down
Up
Up
E622
The marking is not finished until the work is
passed through the marking field.
―
Up
Down
Down
Reference
•
There might be the case that the marking is impossible even though adjusting the waiting time of the marking of the
flying object if there are a lot of marking data.
•
When the pulse output from the encoder and actual motion of the line is not matched, the marking may not performed
properly.
ME-LPMSZ-OP-7
Summary of Contents for LP-M Series
Page 11: ...1 Basic Operation Procedure ME LPMSZ OP 7 ...
Page 76: ...76 MEMO ME LPMSZ OP 7 ...
Page 77: ...2 Description of Operation Screen ME LPMSZ OP 7 ...
Page 102: ...102 Symbol ME LPMSZ OP 7 ...
Page 255: ...Troubleshooting ME LPMSZ OP 7 ...
Page 276: ...Appendix ME LPMSZ OP 7 ...
Page 304: ...Index ME LPMSZ OP 7 ...
Page 307: ...No 9000 0063 56V ...
Page 308: ... Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 56V ...