237
Laser Output Optimize
[Function specific to LP-M5xx / LP-M2xx / LP-Sxxx type]
*
This function is not implemented in the LP-Z series / LP-MAxx / LP-SxxxW type.
Using “Laser Output Optimize” function improves the accuracy of “Laser output measurement/correction” results.
After the installation, replacement or moving of laser marker, use this “Laser Output Optimize” function by following the
procedures as described below.
To use this function
•
This function requires the commercially available laser power meter.
•
Use a calibrated laser power meter.
•
Use a laser power meter that has the damage threshold (max. power density) of more than 10kW/cm
2
.
•
The laser detector diameter of the laser power meter should be more than 10 mm.
•
Adjust the power correction rate using this function every time when the laser marker installation condition is changed.
•
The measurement results might have +/-5% difference with normal temperature (20 to 30 Celsius degree).
•
The +/-10% difference might occur under the high/low temperature. Correcting power under normal temperature is
recommended.
• Before using this function, confirm the laser emission port is clean. The contamination or scratch on the laser emission
port might be a cause of inaccurate results of the laser power measurement.
•
Laser Output Optimize function is available when laser pumping is completed, and the internal shutter is closed.
•
For LP-M5xx / LP-M2xx type, laser output optimize function is available when the laser gate is opened.
•
After using the function, the marking energy measurement results may change.
Confirm the measurement result of the marking energy and adjust “Marking Energy Upper/Lower Limit” value, especially
in case “Marking Energy Upper/Lower Limit” is set with small value.
Optimization procedure
1.
Press [MEASURE/CORRECT] on the
“Environment” - “Environment 3” screen.
2.
“Laser Power Measurement” screen is displayed.
Press [OPTIMIZE].
ME-LPMSZ-OP-7
Summary of Contents for LP-M Series
Page 11: ...1 Basic Operation Procedure ME LPMSZ OP 7 ...
Page 76: ...76 MEMO ME LPMSZ OP 7 ...
Page 77: ...2 Description of Operation Screen ME LPMSZ OP 7 ...
Page 102: ...102 Symbol ME LPMSZ OP 7 ...
Page 255: ...Troubleshooting ME LPMSZ OP 7 ...
Page 276: ...Appendix ME LPMSZ OP 7 ...
Page 304: ...Index ME LPMSZ OP 7 ...
Page 307: ...No 9000 0063 56V ...
Page 308: ... Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 56V ...