Marking energy range: MEN
[Supported models: LP-Mxxx/LP-Sxxx]
Sets thresholds for determination of whether the result of marking energy measurement is in the normal range.
Setting / Readout data marking energy upper/lower limits
STX
MEN
Sub
command
[Upper limit] [lower limit]
18-byte
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request out marking energy upper/lower limits
STX
MEN
R
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Upper limit
9
“000000000”: OFF
“000000100”–“999999999” [mJ]
If the upper limit is not “000000000”, the
lower limit should be less than the upper
limit.
Sets the threshold of the marking energy.
Lower limit
9
ME-LPMSZ-SR-9