15
1-2-3 Shift to remote mode
To control the laser marker externally using I/O or serial communication commands, set the operation mode to the remote
mode in one of the following methods.
Select the method to switch to the remote mode by setting the DIP switch on the rear side of the controller.
Use the remote switch on the front of the controller.
Turn ON the remote mode switch on the front of the controller.
Turn OFF the DIP switch No. 5.
Refer to “1-2-1 DIP switch setting” (P.12).
Use input signal of X5 “REMOTE IN” on I/O terminal.
Turn ON the remote mode input (X5) of the I/O terminal on the rear of the controller.
X5: REMOTE IN
Turn ON the DIP switch No. 5.
Refer to “1-2-1 DIP switch setting” (P.12).
Reference
•
When DIP switch No. 5 is ON, the remote switch on the controller is not available.
Start the laser marker in the remote mode
The laser marker starts up always in the remote mode state. Use the remote mode switch button of the controller for
releasing and resetting the remote mode.
ヱヰヸユ
ン
ON
OFF
Turn OFF the DIP switch No. 5 and turn ON the DIP
switch No. 6.
Refer to “1-2-1 DIP switch setting” (P.12).
Reference
•
When DIP switch No. 6 is ON, “X5: REMOTE IN” signal on I/O terminal is not available.
•
The remote switch on the controller is available when DIP switch No. 6 is ON.
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...