181
Warning
Errors that notify of that the setting data are incorrect or laser radiation conditions are not met are output as warnings.
Marking operation cannot be started while any warning is active. Laser pumping maintains the state before the warning.
Release method of warning
1.
Remove a cause of warning. If the warning cause is the wrong setting, correct the file data.
2. When the laser marker is under the remote mode, close the shutter by I/O or serial communication control.
In case of the following warning, the shutter control is unnecessary.
• E800: the warning occurs only while the specified one-shot output time and it is released automatically.
•
E811: the warning occurs only during the laser stop 1 and OUTCOM. is opened, and then it is released automatically
when the laser stop 1 and OUTCOM. is closed.
3.
If the warning occurs during the marking operation of the files in which the counter function is set, check if the counter
value is correct before restart the marking operation.
4. In case that marking is executed again, make sure that the warning output is turned on, and then open the internal
shutter.
ERROR
CODE
Error description
Measures
E227
Laser gate is not open.
•
Since the returning to the original position of the laser
gate is not performed correctly, the laser gate cannot
be opened.
•
The laser gate is not opened when the test marking,
laser check radiation, or laser power measurement is
started.
•
Input the laser gate control signals for the
returning to the original position after start-up
of the laser marker.
•
Before starting the test marking, laser check
radiation, or laser power measurement , input
the control signal to [L-GATE OP IN] on the
laser gate terminal from the external control
device.
E251
Detected a decrease in clock battery voltage. Reset date
and time.
Contact to our sales office.
While laser Marker power is on, reset “Date and
Time” in Environment Setting. When the power is
off, reset “Date and Time”.
E500
There is not enough free space.
The file cannot be registered.
Delete registered file and logo file.
E501
Cannot register setting because of memory error.
•
Restart with key switch.
• When not recovered, contact our sales office.
E502
E503
Invalid file format in font file and logo file.
• Register the logo or font file again on the USB
screen.
• For the logo file, convert the logo data to
VEC format again with Logo data conversion
software.
E600
No setting file.
Set the marking data such as character, barcode
and logo.
E601
No font file.
• Register font file.
•
Set a registered font to the font in character
condition.
E602
Lack of font memory.
Make font file smaller, or delete unnecessary font
file.
E603
No logo file.
Register logo file.
E604
Included character not registered into font file.
Change characters.
Or set the font file containing the setting
characters.
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...