89
■
Serial offset: SEO
Sets the coordinates specified for “Serial offset function” to change coordinates for each marking.
Serial offset setting
STX
SEO
S
[X offset] [Y offset] [Z offset]
[
θ
offset] [Laser power correction]
34-byte
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
X offset
8
Model type*
Setting range [mm]
LP-Sxx0(W)
“-045.000”–“+045.000”
LP-Sxx5(W)
“-080.000”–“+080.000”
LP-Sxx2
“-027.500”–“+027.500”
LP-Mxx0/LP-Zxx0
“-060.000”–“+060.000”
LP-Mxx5
“-110.000”–“+110.000”
LP-Mxx6/LP-Zxx6
“-165.000”–“+165.000”
Y offset
8
Z offset
(Effective only
LP-M / LP-Z
series)
8
Model type*
Setting range [mm]
LP-Sxxx(W)
“+000.000” (fixed)
LP-Mxxx
“-022.000”–“+022.000”
LP-Zxxx
“-025.000”–“+025.000”
•
LP-Sxxx/LP-SxxxW
:
As this item is not available for the
LP-S series, set to “+000.000”.
•
LP-Mxxx/LP-Zxxx
:
The offset of Z coordinate is
indicated.
θ
offset
7
“-180.00”–“+180.00”
Laser power
correction
3
“000”–“999” [%]
The correction ratio is calculated using
the value set at the laser condition as
100%.
* For the detail of the model type, refer to “Target laser marker” (P.4).
Reference
•
The command for serial offset input is enable when serial offset is set with external offset condition.
•
Transmission is available only during remote control and when the internal shutter is opened (“Reception mode ON” is
not set for command reception permission (MKM command)).
•
Set “Serial Offset” for “External Offset Condition” before using this command.
•
When using this function (serial offset), transmit this command by every marking. Otherwise it does not become marking
ready condition, and marking is not available.
•
For resetting the data, either set “reception mode ON” for the command reception permission (MKM command), or close
the shutter.
•
SEO command cannot be used with the rank function and equidistant marking to moving object.
• If SEO command is used with the marking to the flying object, make sure that the marking interval time is enough to the
required period to input the marking data and to confirm the marking ready output.
•
Refer to “Timing chart for serial offset marking” (P.90) for the timing chart for this command transmission.
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...