94
■ Step & repeat fine adjustment: SRA
Sets the fine adjustment of “Step & repeat” to mark the same marking contents on multiple locations in one file.
Setting / Readout data of step & repeat fine adjustment
STX
SRA
Sub
command
[List line] [Fine adj. type]
[Varies depending on the type of line adj.]
Max. 605-byte
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request of step & repeat fine adjustment
STX
SRA
R
[List line]
4-byte
(Check sum)
Delimiter
1. Setting deletion (data length: max. 9-byte)
Name
Data length
[byte]
Description
Remarks
List line
4
“0000”–“0399”
Fine adj. type
1
“0”: Setting deletion
Number of
delete line
(4)
“0001”–“0400”
If only the first line in the list line will be deleted, the setting
can be omitted.
2.
In case of “Single” as fine adjustment type (data length: max. 45-byte)
Name
Data length
[byte]
Description
Remarks
List line
4
“0000”–“0399”
Fine adj. type
1
“1”: Single fine adjustment
Target row
3
“001”–“400”
Target column
3
“001”–“400”
Fine tune X
8
Model type*
Setting range [mm]
LP-Sxx0(W)
“-045.000”–“+045.000”
LP-Sxx5(W)
“-080.000”–“+080.000”
LP-Sxx2
“-027.500”–“+027.500”
LP-Mxx0/LP-Zxx0 “-060.000”–“+060.000”
LP-Mxx5
“-110.000”–“+110.000”
LP-Mxx6/LP-Zxx6
“-165.000”–“+165.000”
Fine tune Y
8
Fine tune Z
(Effective only
LP-M / LP-Z
series)
8
Model type*
Setting range [mm]
LP-Sxxx(W)
“+000.000” (fixed)
LP-Mxxx
“-022.000”–“+022.000”
LP-Zxxx
“-025.000”–“+025.000”
•
LP-Sxxx/LP-SxxxW
:
As this item is not available for the
LP-S series, set to “+000.000”.
•
LP-Mxxx/LP-Zxxx:
Specifies the amount of adjustment
for Z axis.
Rotation angle
*2
(7)
“-180.00”–“+180.00” [°]
Laser power
adjustment *2
(3)
“-50”–“+50” [%]
*1 : For the detail of the model type, refer to “Target laser marker” (P.4).
*2 : When both setting values of the rotation angle and laser power adjustment are “0”, those settings can be omitted.
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...