109
3-5-4 Guide laser
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
T1
SHUTTER
OUT *1
READY OUT
GUIDE IN
SELECT 0 to 2 IN
SHUTTER B IN
SHUTTER A IN
(Open)
(Close)
*1 : Shutter output signal has around 200ms to max. 1 sec. delay from each input signal for the shutter open / close
operation time.
The operation behavior of Shutter 2 output on LP-Sxxx-SF/LP-Sxxx-LS1 type is the same as Shutter output.
Item
Time
Remarks
T1
0.5 ms or more
After a lapse of 0.5ms or more from specifying SELECT 0 IN to SELECT 2 IN, turn on
GUIDE IN.
Select the guide laser radiation details by the select input. Turn on the guide laser radiation input by entering the SELECT 0
to 2 input as shown in the below table.
Radiation details
SELECT 0
SELECT 1
SELECT 2
Dual pointer
OFF
OFF
OFF
Marking contents
ON
OFF
OFF
Marking field
OFF
ON
OFF
Work image
ON
ON
OFF
ンㄆㄇㄆㄓㄆㄏㄆ
• You can use the guide laser regardless of the input status of LASER STOP 1 in I/O terminal, but you cannot use the
guide laser while LASER STOP 2 is opened.
• For LP-Sxxx-LS1 type, you can use the guide laser even when the interlock connector is opened under the remote
mode. For other models, you cannot control the guide laser by I/O when the interlock connector is open.
• Guide indication by I/O guide laser input is unavailable when the No. 2 DIP switch on the back surface of controller is
turned to ON.
• If inputting GUIDE IN repeatedly, turn ON GUIDE IN at intervals of more than 500 msec.
ME-LPS-SSM-8
Summary of Contents for LP-S Series
Page 15: ...15 MEMO ME LPS SSM 8 ...
Page 26: ...26 Chapter 1 Specification ME LPS SSM 8 ...
Page 41: ...41 Chapter 2 Preparation ME LPS SSM 8 ...
Page 78: ...Chapter 3 Connection for External Control ME LPS SSM 8 ...
Page 126: ...Chapter 4 Maintenance ME LPS SSM 8 ...
Page 148: ...Troubleshooting ME LPS SSM 8 ...
Page 169: ...Index ME LPS SSM 8 ...
Page 172: ...172 MEMO No 9000 0066 16V ME LPS SSM 8 ...
Page 173: ...No 9000 0066 16V ...