111
3-5-6 Time hold input and date gap output
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Actual date
Example: 15 o’clock at Day 1
Marking with
the time at
ON
(3 p.m. at Day 1)
Marking with
the time at
ON
(3 p.m. at Day 1)
8 a.m. at Day 2
Re-dating
Day 1
Day 2
READY OUT
GAP OUT
MARKING OUT
TRIG. IN
TIME HOLD IN
(Marking with the time
at 8 a.m. at Day 2)
ンㄆㄇㄆㄓㄆㄏㄆ
• The time at system startup is held when the laser marker is turned to on with the TIME HOLD ON.
• If the TIME HOLD is set ON, the time is held in spite of switching the file No.
• If the TIME HOLD ON/OFF is switched in short time, each ON/OFF hold time should be more than 2 seconds.
3-5-7 Counter end output
T1
T1
T1
T1
ON
OFF
ON
OFF
ON
OFF
ON
OFF
The end value is marked.
COUNTER END OUT
(CEND 0 to 7)
MARKING OUT
TRIG. IN
READY OUT
Item
Period
Remarks
T1
10 ms or more
Keep the ON status for 10 ms or more.
ンㄆㄇㄆㄓㄆㄏㄆ
• The counter end output remains turned ON with the shutter open until the next marking trigger is input. When you close
the shutter, the counter end output turns OFF.
• When “Step & Repeat counter at each step” function is set, counter end output is invalid.
ME-LPS-SSM-8
Summary of Contents for LP-S Series
Page 15: ...15 MEMO ME LPS SSM 8 ...
Page 26: ...26 Chapter 1 Specification ME LPS SSM 8 ...
Page 41: ...41 Chapter 2 Preparation ME LPS SSM 8 ...
Page 78: ...Chapter 3 Connection for External Control ME LPS SSM 8 ...
Page 126: ...Chapter 4 Maintenance ME LPS SSM 8 ...
Page 148: ...Troubleshooting ME LPS SSM 8 ...
Page 169: ...Index ME LPS SSM 8 ...
Page 172: ...172 MEMO No 9000 0066 16V ME LPS SSM 8 ...
Page 173: ...No 9000 0066 16V ...