137
4.
Install the laser power meter to measure the laser power.
Place the detector of the laser power meter at the following distance, i.e. one-third to half of the focal length (specified
work distance) of the laser marker.
Laser marker model name
Setting distance of detector of the power meter
LP-S502, LP-S202
Approx. 45 mm
LP-S500, LP-S200
Approx. 65 mm
LP-S505, LP-S205
Approx. 120 mm
* The setting distance shown above is the recommended value for detector of the laser power meter with the damage
threshold (max. power density) of more than 10kW/cm
2
.
Head part of the laser marker
Detector of the laser power meter
Laser beam
Marking object
Setting distance of detector
of the power meter
Work distance
(Base position)
CAUTION
• Do not place the power meter detector at the focal point (specified work
distance) of the laser marker. It may cause damage to the power meter.
5.
Confirm the setting position of detector of the power
meter.
Press [GUIDE].
Select [Dual Pointer], and press [START].
The dual pointer is will deactivate by pressing [STOP].
Light is received in the power meter on the center of the cross indicator in
the dual pointer mode. Never place the detector where the point indicator is
overlapping with the dot indicator, that indicates the focal point of the laser.
ME-LPS-SSM-8
Summary of Contents for LP-S Series
Page 15: ...15 MEMO ME LPS SSM 8 ...
Page 26: ...26 Chapter 1 Specification ME LPS SSM 8 ...
Page 41: ...41 Chapter 2 Preparation ME LPS SSM 8 ...
Page 78: ...Chapter 3 Connection for External Control ME LPS SSM 8 ...
Page 126: ...Chapter 4 Maintenance ME LPS SSM 8 ...
Page 148: ...Troubleshooting ME LPS SSM 8 ...
Page 169: ...Index ME LPS SSM 8 ...
Page 172: ...172 MEMO No 9000 0066 16V ME LPS SSM 8 ...
Page 173: ...No 9000 0066 16V ...