160
Others
Troubles
Causes
Measures
Laser is emitted at
unintended timing.
Photoelectric sensor for marking trigger
signal malfunctions.
Fumes may cause malfunction of photoelectric
sensor for marking trigger signal.
• Install dust collector.
• Check that dust collector works well.
Date is reset.
Internal battery has run out.
Contact failure may also be a cause of this
symptom. When laser marker have been in use
for five years or more, internal battery is easy to
run out.
Contact our sales office for replacement of
internal battery.
A USB flash drive cannot
be recognized.
• A USB flash drive with a security
function is used.
• The file system selected when
formatting the USB flash drive is not
appropriate.
• The connector of the USB flash
drive is dirty.
• The laser marker was launched with
the USB flash drive connected.
• USB flash drives with a security function
cannot be used.
• Use a USB flash drive formatted with FAT32.
• Clean the connector according to the
procedure in the instruction manual of your
USB flash drive.
• Insert the USB flash drive after the activation
of the laser marker is completed.
ME-LPS-SSM-8
Summary of Contents for LP-S Series
Page 15: ...15 MEMO ME LPS SSM 8 ...
Page 26: ...26 Chapter 1 Specification ME LPS SSM 8 ...
Page 41: ...41 Chapter 2 Preparation ME LPS SSM 8 ...
Page 78: ...Chapter 3 Connection for External Control ME LPS SSM 8 ...
Page 126: ...Chapter 4 Maintenance ME LPS SSM 8 ...
Page 148: ...Troubleshooting ME LPS SSM 8 ...
Page 169: ...Index ME LPS SSM 8 ...
Page 172: ...172 MEMO No 9000 0066 16V ME LPS SSM 8 ...
Page 173: ...No 9000 0066 16V ...