33
Item
Model
LP-S500W
LP-S505W
Power voltage
90V AC to 132V AC or 180V AC to 264V AC
(including voltage fluctuation range of ±10%) *9
Frequency: 50/60 Hz
Power consumption
100V AC
470VA or less
200V AC
650VA or less
Grounding method
Head and controller: Direct earth
Cooling method
Head: Natural air-cooling, Controller: Forced air-cooling
Operating ambient temperature *11
0 °C to +40 °C
Ambient temperature for storage *11
-10 °C to +60 °C
Operating ambient humidity *11
35 to 85%RH
Protection degree *12
Head: IP67G (excluding the controller)
Overvoltage category
Ⅱ
Pollution degree
2
Use location
Indoor; at an altitude of 1000 m or below
Fiber cable length
5 m +/- 0.2 m, minimum bent radius 50 mm
Installation
direction
Head
Omnidirectionally
Controller
Vertically or horizontally
Main unit weight
Head
Approx. 6.5kg
Approx. 7kg
Controller
Approx. 24kg
Battery
(embedded in
product)
Type
Graphite fluoride lithium battery
Model
BR-1 / 2AAC2P
Quantity / Weight
1 piece / Approx. 9.5g
*1 : Average output power from the laser marker at delivery time with the maximum laser power setting.
*2 : Work distance reference position represents the calculated center position of the work distance range. Depending on
objects to be marked, optimal distance may vary.
*3 : Work distance range represents the configurable work distance. Depending on objects to be marked, optimal distance
or markable range may vary.
*4 : The value shown here is the configuration range that can be input. The setting values that can keep the quality of
marking or processing vary depending on the marking conditions and the target materials.
*5 : For using SQRC, an extra-cost software is needed. SQRC marking function is available only for use in Japan.
*6 : VEC is a usable format of graphic file for laser marker. To use HPGL, BMP or JPEG files, convert them to VEC format
with the attached “Logo Data Conversion software”. To use AI or EPS files, convert them to VEC format with the
attached software “ExportVEC”.
*7 : Check the operation before use. Use a USB flash drive formatted with FAT32. USB media with security features
cannot be used.
*8 : OS versions of which Microsoft has ended support are excluded.
*9 : The power voltage is auto-switched.
*10 : The typical value of the inrush current at system startup is as follows. (Duration time is 10 ms or less.)
100V AC: 80A / 200V AC: 160A
*11 : This specification is applied to both head and controller. No condensation and freezing shall be allowed. If there is
a gap between the stored temperature and operating temperature, make sure to have the product get used to the
operating ambient temperature gradually prior to use to prevent the dew condensation.
*12 : For the oil proof condition, refer to “About protection grade (dustproofness, waterproofness and oilproofness)” (P.34).
ME-LPS-SSM-8
Summary of Contents for LP-S Series
Page 15: ...15 MEMO ME LPS SSM 8 ...
Page 26: ...26 Chapter 1 Specification ME LPS SSM 8 ...
Page 41: ...41 Chapter 2 Preparation ME LPS SSM 8 ...
Page 78: ...Chapter 3 Connection for External Control ME LPS SSM 8 ...
Page 126: ...Chapter 4 Maintenance ME LPS SSM 8 ...
Page 148: ...Troubleshooting ME LPS SSM 8 ...
Page 169: ...Index ME LPS SSM 8 ...
Page 172: ...172 MEMO No 9000 0066 16V ME LPS SSM 8 ...
Page 173: ...No 9000 0066 16V ...