21
7.2.
When Replacing the Main P.C.B.
After replacing the MAIN P.C.B., be sure to achieve adjustment.
The adjustment instruction is available at “software download” on the “Support Information from NWBG/VDBG-AVC” web-site in
“TSN system”, together with Maintenance software.
7.3.
Service Position
This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.
Table S1 Extension Cable List
CAUTION-1. (When servicing FLASH TOP P.C.B.)
1. Be sure to discharge the E.capacitor on FLASH TOP P.C.B..
Refer to “HOW TO DISCHARGE THE E.CAPACITOR ON FLASH TOP P.C.B.”.
The E.capacitor voltage is not lowered soon even if the AC Cord is unplugged or the battery is removed.
2. Be careful of the high voltage circuit on FLASH TOP P.C.B..
3. DO NOT allow other parts to touch the high voltage circuit on FLASH TOP P.C.B..
No.
Parts No.
Connection
Form
1
RFKZ0581
FP9001 (MAIN) - CCD UNIT
47PIN 0.3FFC
2
RFKZ0416
FP9002 (MAIN) - LENS UNIT
41PIN 0.3FFC
3
RFKZ0416
FP9003 (MAIN) - LCD UNIT
41PIN 0.3FFC
4
RFKZ0418
PP9001 (MAIN) - PS8001 (FLASH TOP)
30PIN B to B
5
RFKZ0553
PS9001 (MAIN) - PP9501 (SUB)
16PIN B to B