16
•
5. How to returned to Normal Display:
Turn the power off and on, to exit from Error code display mode.
NOTE:
The error code can not be initialized.
SOFT
CPU
Reset
3000
0001
|
0007
NMI reset
Non Mask-able Interrupt
(30000001-30000007 are caused by factors)
Card
Card
3100
0001
Card logic error
SD card data line or IC6001 (VENUS 3)
0002
Card physical error
SD card data line or IC6001 (VENUS 3)
0004
Write error
SD card data line or IC6001 (VENUS 3)
3900
0005
Format error
CPU,
ASIC hard
Stop
3800
0001
Camera task finish process time out.
Communication between Lens system and IC6001 (VENUS 3)
0002
Camera task invalid code error.
IC6001 (VENUS 3)
0100
File time out error in recording motion image
IC6001 (VENUS 3)
0200
File data send error in recording motion image
IC6001 (VENUS 3)
0300
Single or burst recording brake time out.
Operation
Power on
3B00
0000
FLASHROM processing early period of camera during movement.
Zoom
Zoom
3C00
0000
I do not complete zoom lens processing
Zoom lens
3500
0000
I jumped into dummy processing
(0-7bit : command, 8-15bit : Status)
3501
0000
Though record preprocessing is necessary, it is not called.
3502
0000
Though record preprocessing is necessary, it is not completed.
Attribute
Main item
Sub item
Error code
Contents (Upper)
High 4 bits Low 4 bits
Check point (Lower)
Summary of Contents for LUMIX DMC-FX50EB
Page 8: ...8 NOTE Above caution is applicable for a battery pack which is for DMC FX50 series as well ...
Page 12: ...12 4 Specifications ...
Page 13: ...13 5 Location of Controls and Components ...
Page 20: ...20 8 Disassembly and Assembly Instructions 8 1 Disassembly Flow Chart 8 2 PCB Location ...
Page 28: ...28 ...