18
7.3.
Service Position
This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.
Table S1 Extension Cable List
CAUTION-1. (When servicing FLASH TOP PCB)
1. Be sure to discharge the capacitor on FLASH TOP PCB.
Refer to “How to Discharge the Capacitor on Flash top PCB”.
The capacitor voltage is not lowered soon even if the AC Cord is unplugged or the battery is removed.
2. Be careful of the high voltage circuit on FLASH TOP PCB.
3. DO NOT allow other parts to touch the high voltage circuit on FLASH TOP PCB.
No.
Parts No.
Connection
Form
1
VFK1951
FP9001 (MAIN) - MASTER FLANGE UNIT
39PIN 0.3 FFC
2
VFK1978
FP9002 (MAIN) - CCD UNIT
31PIN 0.3 FFC
3
VFK1950
FP9003 (MAIN) - LCD UNIT
33PIN 0.3 FFC
4
VFK1974
FP9004 (MAIN) - LCD UNIT
4PIN 0.5 FFC
5
VFK1870
PP9001 (MAIN) - PS8001 (FLASH TOP)
30PIN B to B