20
7.2.
When Replacing the Main PCB
After replacing the MAIN PCB, be sure to achieve adjustment.
The adjustment instruction is available at “software download” on the “Support Information from NWBG/VDBG-PAVC” web-site in
“TSN system”, together with Maintenance software.
7.3.
Service Position
This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.
Table S1 Extension Cable List
7.3.1.
Extension Cable Connections for DMC-TZ3
No.
Parts No.
Connection
Form
1
VFK1950
FP9801 (MAIN) - CCD UNIT
33PIN 0.3 FFC
2
RFKZ0416
FP9802 (MAIN) - LENS UNIT
41PIN 0.3 FFC
3
RFKZ0363
FP9803 (SUB) - FP9901 (FLASH)
19PIN 0.5 FFC
4
RFKZ0363
FP9005 (MAIN) - FP8001 (TOP OPERATION)
19PIN 0.5 FFC
5
RFKZ0363
FP9001 (MAIN) - LCD UNIT (For DMC-TZ3)
19PIN 0.5 FFC
FP9002 (MAIN) - LCD UNIT (For DMC-TZ2)
6
VFK1974
FP9003 (MAIN) - LCD UNIT (For DMC-TZ3)
4PIN 0.5 FFC
FP9004 (MAIN) - LCD UNIT (For DMC-TZ2)
7
RFKZ0362
PS9801 (SUB) - PP9001 (MAIN)
100PIN B to B