background image

Suction 
Tube

Discharge
Tube

4 holes

19mm (0.75") DIA

205.1mm (8.07")

165.1mm (6.50")

131.6mm

(5.18")

101.6mm

(4.00")

86mm

(3.39")

91mm

(3.56")

Process Tube

87mm

(3.43")

111 mm

(4.37")

49 mm

(1.93")

88mm

(3.46")

F

B

A

C

D

E

185.4mm DIA

(7.30")

12.2mm (0.48")

Running 
Capacitor

Compressor
Motor

Motor Protector

M

C

S

~

3

2

Dimensions*

mm

inches

A

 . . . . . . . . . . . . . . . . . . . . . 211.8  . . . . . . . . . . . . . . . . . . . 8.34

B

 . . . . . . . . . . . . . . . . . . . . . 84.2 . . . . . . . . . . . . . . . . . . . . 3.31

C

 . . . . . . . . . . . . . . . . . . . . . 127.6 . . . . . . . . . . . . . . . . . . . 5.02

D

 . . . . . . . . . . . . . . . . . . . . . 82.9 . . . . . . . . . . . . . . . . . . . . 3.26

E

 . . . . . . . . . . . . . . . . . . . . . 70.4 . . . . . . . . . . . . . . . . . . . . 2.77

F

 . . . . . . . . . . . . . . . . . . . . . 75.2 . . . . . . . . . . . . . . . . . . . . 2.96

*

All dimensions are for reference only

Tubes

Tube O.D.

Wall

Material

Suction . . . . . . . . . .0.393 in. / 10 mm 0.037 in. / 0.95 mm Copper

Process  . . . . . . . . . 0.33 in. / 8.3 mm

0.035 in. / 0.9 mm Copper

Discharge . . . . . . . . 0.33 in. / 8.3 mm

0.035 in. / 0.9 mm Copper

U.L. File #

 . . . . . . . . . SA 4615

C.S.A. File #’s

 . . . . . . LR - 36593

General Data

Oil Charge . . 250 cc ± 5 cc / 15.3 cu.in. ± 0.3 cu.in.

Net Weight With Oil  . . . . . . . . . . . 22.0 lbs, 10.0 kg

Approved Oils:

FREOL  . .

α

10, 

α

10E, 

α 

15, 

α 

15E, 

α 

22, 

α

22E

ICI  . . . . . . . . . . . . . . . . . RL10H, RL15H, RL22H

HENKEL  . . . . . . . . . . . . . .ProEco 10S,15S, 22S

Residual Moisture  . . . . . . . . . . . . . . . 120 mg max.

Impurities  . . . . . . . . . . . . . . . . . . . . . . 10 mg max.

Displacement  . . . . . . . . . . . 7.27 cc. / 0.444 cu. in.

Panasonic Industrial Company

Refrigeration Products Department

Tel:  201 - 392 - 4249

Fax: 201 - 392 - 4315

Rev#1-5/9

This document sets forth certain operational parameters and conditions for
operation of this product. If this product is operated outside of the parameters
and conditions stated herein, buyer assumes sole and full responsibility and
shall indemnify seller with respect to all product failures and all consequences
thereof. Operation of the product outside of the parameters and conditions
specified herein shall serve to invalidate all seller warranties, if any, with respect
to the product. This document is for reference only. For specifications, please
contact Panasonic’s engineering department.

MATSUSHITA 

Compressor

Single Phase

115 V

MODEL# DC73C12RCU6

R-134a

60 Hz     

Panasonic

®

Reviews: