3.2.2. Installation
1. Place the vacuum cleaner in the upright position standing
on the handle. This will minimize wheel interference when
removing the lower plate.
2. Reinstall lower plate by (1) aligning tabs with the slots in the
nozzle and (2) rotating the lower plate to installed position.
3. Lay vacuum cleaner with bottom facing upwards and nozzle
flat.
4. Reinstall four (4) screws into lower plate.
5. Reinstall the nozzle hose into slot on body and slide down
until it clicks in place.
6. Return the vacuum cleaner to the upright position before
plugging into an electrical outlet.
3.3. Agitator
3.3.1. Removal
1. Remove lower plate (See Lower Plate - Removal).
2. Lay vacuum cleaner with bottom facing upwards and nozzle
flat
3. Remove agitator carefully lifting out.
3.3.2. Installation
1. Loop new belt around motor shaft and agitator belt groove.
2. MC-UG327 ONLY -- Belt must be looped around motor
shaft, not carpet/bare floor selector shaft. See illustration for
correct belt routing. NOTE: Shifter must be in carpet
position when installing the belt.
3. Reinstall agitator into lower plate by placing end caps in
grooves.
4. After reinstalling, turn agitator by hand to make sure belt is
not twisted or pinch and that all rotating parts turn freely.
5. Replace lower plate (See Lower Plate - Installation).
NOTE: For general servicing, it is necessary to eliminate
pinching of any wire during reassembly. After servicing
14