FAULT: Site specific data (SSD), CU nn
YYYY-MM-DD HH:MM
This text message means that the SSD have
not
been downloaded
properly, i.e. a new download has to be performed.
19.3
Control Units in a TLON network
The SSD for all control units can be downloaded via a PC (WinG3),
connected to one control unit. The download will be performed to the
control units, one at a time, according to the chapter "Single Control
Unit" above. The download is performed in a consecutive order, i.e.
0-1-2-3-4-……-29 amongst the selected control units
but
the control
unit where the PC is connected will automatically be the last one to
get the SSD downloaded.
When the SSD download to a control unit is completed, that control
unit will automatically restart, see chapter "Restart", page 81.
19.4
User definable text messages download
When a fire alarm is activated (e.g. an addressable alarm point), the
presentation number (Zone - Address) will be shown in the control
unit display as well as in the ext. FBP 1826 / 1828 display
38
. There
will also be shown a user definable alarm text, if programmed. See
page 40.
Each alarm point can have a unique text message.
Each zone can have a unique text message.
Each zone line input can have a unique text message.
The user definable text messages will be printed out when a printer is
available.
See also chapter "Fire alarm", page 39.
All user definable text messages, up to 40 alphanumeric characters
each, are created and downloaded via
WinG3
. See Planning
Instructions, chapter "User definable text messages".
38
This is also valid for the Ext. Presentation unit 1728 and the Alert
Annunciation units 1735 / 1736.