No. SX-DSV02472 -
117-
(2) Warning types
General warning
Warning
No.
(Hex.)
Warning
Content
Output setting
Waning mask
Pr 4.40/
Pr 4.41
*1)
Pr 6.38
Corresponding
bit
*2)
A0
Overload protection
Load factor is 85% or more the protection level.
1
bit 7
A1
Over-regeneration
warning
Regenerative load factor is 85% or more the
protection level.
2
bit 5
A2
Battery warning
Battery voltage is 3.2 V or lower.
3
bit 0
A3
Fan warning
Fan has stopped for 1 sec.
4
bit 6
A4
Encoder
communication
warning
The number of successive encoder
communication errors exceeds the specified
value.
5
bit 4
A5
Encoder overheat
warning *3)
The encoder detects overheat warning.
6
bit 3
A6
Oscillation
detection warning
If Pr6.37 (oscillation detection level) is
non-zero, it is detected that the torque
oscillation (oscillation state) than that specified
in Pr6.37.
7
bit 13
A7
Lifetime detection
warning
Life expectancy of capacitor or fan becomes
short.
8
bit 2
A8
External scale error
warning
(Not supported)
The external scale detects the warning.
9
bit 8
A9
External scale
communication
warning
(Not supported)
The number of successive external scale
communication errors exceeds the specified
value.
10
bit 14
Extended warning
Warning
No.
(Hex.)
Warning
Content
Output
setting
Waning mask
Pr 4.40/
Pr 4.41
*1)
Pr 6.38
Corresponding
bit
*2)
C3
Main power off
warning
When setting of Pr7.14 (Main power off
warning detection time) is 10-1999,
instantaneous power interruption occurs
between L1 and L3 and lasts for a time longer
than the setting of Pr7.14.
14
bit 12
R1.05
Motor Business Division, Appliances Company, Panasonic Corporation