No. SX-DSV02829 -
33-
3-5 Station alias
Station alias can be set up by the following three methods.
1) Reading the value of SII from Configured Station Alias
Reading the value of 0004h(Configured Station Alias) in the SII from 0012h(Configured Station Alias)
of ESC register.
2) Reading the value of rotary switch from Configured Station Alias
Reading the value made of object 3740h(Station alias setup(high)) and front panel rotary switch from
0012h(Configured Station Alias) of ESC register.
3) Reading the value of rotary switch from AL Status Code (Explicit Device ID)
Reading the value made of object 3740h(Station alias setup(high)) and front panel rotary switch from AL
Status Code(0134h).
Please refer to 3-8-2 clause " Node addressing (Setting Station alias)" by technical document -EtherCAT
communication specification- (SX-DSV02830) for details.
・
Selection of Station alias
Class
No.
Attrib
ute
*1)
Parameter
Setting
range
Unit
Function
7
40
Station Alias
setup(high)
0 - 255
-
Set the upper 8 bits of station alias.
7
41
A
Station Alias
selection
0 - 2
-
Defines the station alias setting method
Value
Function
0
Setting by rotary switch on front panel, and
by Pr7.40 will be station alias.
1
Value of SII area (0004h) will be station
alias.
2
For manufacturer’s use
R1.00
Motor Business Unit, Panasonic Corporation