No. SX-DSV02829 -
55-
4-7-1 Parameter setting according to linear motor/feedback scale specification
Set up various parameters by referring to the specifications of the linear motor to be connected.
Two motor types are supported: “Linear type” and “Rotary type”.
The same parameter number has different meaning between “Linear type” and “Rotary type”.
For more information, refer to the parameter tables in Sections 4-7-1-1, 4-7-1-2.
4-7-1-1 Linear type motor
■Relevant parameter: Linear type
Class No.
At-
trib-
ute
*1)
Title
Range
Unit
Function
9
00
R
Motor type
0-2
-
Select the type of the motor to be connected.
1: linear type, 2: rotary type
If the setting value is zero, Err60.0 “Motor setting error protection”
occurs.
9
01
R
Feedback scale
resolution / number
of scale pulses per
revolution
0-
16777216
0.001
μm
Set the feedback scale resolution.
The valid range is2048 to 16777216. If out of range, Err60.0 “Motor
setting error protection” occurs.
9
04
R
Motor movable
part mass/
motor inertia
0-32767
0.01kg
Set the movable part mass of the motor.
If the setting value is zero, Err60.0 “Motor setting error protection”
occurs.
9
05
R
Motor rated thrust/
motor rated torque
0-32767
0.1N
Set the rated thrust of the motor.
If the setting value is zero, Err60.0 “Motor setting error protection”
occurs.
9
06
R
Motor rated
effective current
0-32767
0.1
Arms
Set the rated current of the motor.
If the setting value is zero, Err60.0 “Motor setting error protection”
occurs.
Also, if it exceeds allowable rated current of the amplifier, Err60.1
“Motor combination error 1” occurs.
9
07
R
Motor maximum
instantaneous
current
0-32767
0.1A
Set the maximum instantaneous current of the motor.
If the setting value is zero, Err60.0 “Motor setting error protection”
occurs.
Also, if it exceeds maximum allowable instantaneous current of the
amplifier, Err60.1 “Motor combination error 1” occurs.
9
10
R
Maximum
overspeed level
0-20000
mm/s
Set the maximum overspeed of the motor.
If the setting value is zero, Err60.0 “Motor setting error protection”
occurs.
9
11
R
Carrier frequency
0-1
-
Select the carrier frequency.
0: 6kHz, 1: 12kHz
* The factory default of carrier frequency may vary according to the amplifier
size.
Sizes A, H: 12 kHz, sizes B to G: 6 kHz
* When the carrier is set to 12 kHz in the sizes B to G, a delaying is
necessary. For more information, refer to the delivery specifications.
(To be continued)
R1.00
Motor Business Unit, Panasonic Corporation