No. SX-DSV02829 -
56-
Class No.
At-
trib-
ute
*1)
Title
Range
Unit
Function
9
02
R
Magnetic pole
pitch
0-32767
0.01m
m
Set the magnetic pole pitch.
This setting value is valid only for Pr9.00 “Motor type selection” = 1 (linear
type).
This is not compatible with Pr9.30 “Number of pulses per magnetic pole”.
To set the magnetic pole with this parameter, set Pr9.30 “Number of pulses per
magnetic pole” to zero.
Err60.0 “Motor setting error protection” occurs in the cases below:
Pr9.00=1 (linear type) and Pr9.02=0 and Pr9.30<512
Pr9.00=1 (linear type) and Pr9.02
≠
0 and Pr9.30
≠
0
9
30
R
Number of pulses
per magnetic pole
0-32767000
0
pulse
Set the magnetic pole for the linear motor with the number of pulses.
This value is valid only for Pr9.00 “Motor type selection” = 1 (linear
type).
Setting value = 512 or more: The value is the number of pulses per magnetic
pole.
▪ The setting value becomes effective from 512. But, set it to not less than
2048 as much as possible.
Setting value = pole pitch [mm]
÷
scale resolution [um]
×
1000
This is not compatible with Pr9.02 “Magnetic pole pitch”.
To set the magnetic pole with this parameter, set Pr9.02 “Magnetic pole
pitch” to zero.
Err60.0 “Motor setting error protection” occurs in the cases below:
Pr9.00=1 (linear type) and Pr9.02=0 and Pr9.30<512
Pr9.00=1 (linear type) and Pr9.02
≠
0 and Pr9.30
≠
0
Note: In general, use Pr9.02 “Magnetic pole pitch” for setting the magnetic
pole. If this is the case, make sure to set this parameter to zero.
Use this parameter only if Pr9.02 is exceptionally unavailable.
*1) For information on the parameter attribute, refer to the section 9-1.
R1.00
Motor Business Unit, Panasonic Corporation