No. SX-DSV03335 - 75-
R2.0
Industrial Device Solution Business Unit, Panasonic Corporation
8-5 Mounting direction and interval
· The servo driver is a vertical placement type. Mounting should be vertical.
· The base mount type (rear mounted) is the standard for servo drivers Size A to D and Size H.
· When changing mounting surface with amp of Size A to D, please use the optional mounting bracket.
· Please select the tightening torque of the product fixing screws considering the strength of the screws
and the material of the installation destination.
Example) When mounting with steel screws to steel
Size A to G : M5 2.7 to 3.3 N · m, Size H : M6 4.7 to 5.7 N · m
· To ensure effective cooling, ensure the surrounding space.
· Install a fan to make the temperature inside the control panel uniform.
· The cooling fans are attached to the lower side of the size D - F,
the lower side and the upper side of the size G and H.
· Please observe the environmental conditions in the control panel environment.
· Secure the servo driver to the grounded conductive frame.
· If there is paint on the part where the servo driver or fan is to be installed, if you remove the paint and install it,
there is a possibility of it being effective for noise control.
· In case you install the mounting bracket yourself, there is a possibility that noise countermeasure may be
effective if using conductive plating process.
· The ambient temperature should be measured 50 mm away from the side or bottom of the servo driver.
If it can not be measured at a distance of 50 mm, measure at the midpoint of the gap between the obstacle and the servo driver.
d
10 mm or more
Top
Bottom