9

8

System configuration and wiring/ Wiring

System configuration/ general wiring diagram

Digital key pad

connecting

cable (option)

Connector

for SER.

It cannot be used 

simultaneously.

Digital key pad 

(Option)

 

digital display console.

It enables change of 

parameter.

  refer to the Operating

(

Instructions (Overall). 

)

RS485

Communication software

PANATERM for BL

please download from our web site

Change of parameter seting

monitor of a control state 

Motor extension cable 

(option)

Select if needed (to 10 m). 

Power supply connection connector kit 

(option) 

Personal computer 

(Customer preparation) 

Gear head

(option)

PC connecting cable 

(option) 

* For details of parameters, refer to the Instruction Manual (Overall).

GV/GP series

 Brushless motor

GV/GP series

Brushless Amplifier

Noise

filter

Magnetic

contactor

External

regenerative

resistor

(Option)

MCCB

POWER

It cannot be used 

simultaneously.

AC power supply

Wiring

Standard wiring diagram

• In Case of 3-Phase 200 V

In wiring to power supply (outside of equipment) from MCCB, 

use an electric wire of 1.6 mm diameter (2.0 mm

2

) or more 

both for main circuit and grounding. Apply grounding class D 

(100 Ω or below) for grounding. 

Do not tighten the ground wires together, but connect them 

individually.

Fastening torque of earth screws to be 0.49 to 0.98 N·m.

GV series

GP series

02

Connector

 

for control 

signals (I/O)

External speed setting 

Variable resister 5 kΩ 

B characteristic 1/4 W

change of

Direction 

10

1

01

5V

FIN

GND

I

3

I

4

I

5

I

2

I

1

Run/Stop

command

Brushless

amplifier

Power 

supply

input

L1

L2

L3

1

5

6

10

 Be sure to ground the grounding terminal. 

MCCB

Molded Case

(

Circuit Breaker

)

Grounding

Noise

filter

* When you use single 

phase, connect the 

main power between 

L1 and L2 terminals.

Forced trip

02

Connector

 

for control 

signals (I/O)

10

1

01

5V

NC

GND

I

3

NC

I

4

I

2

I

1

Run start

Point designation

Home sensor

Wiring

Function of terminal

Connector for power supply (POWER)

Connector on Amplifier Side: Part No. 5569-10A1-210 (Molex Inc.) or equivalent

Terminal 

number 

Terminal 

Symbol

Terminal 

name

Terminal explanation 

3

B

terminal for  

Regenerative 

resistor

Please connect Regenerative resistor of an option  if needed.

Regenerative resistor name:

   100 V type   DV0P2890 (50 Ω)

   200 V type   DV0PM20068 (200 Ω)

5

P

6

L3

Terminal for 

Power supply 

input  

Connect the terminal to commercial power supply conforming to 

voltage specification. When you use single phase, connect the main 

power between L1 and L2 terminals.

8

L2

10

L1

1,2,4,7,9

NC

Do not connect anything to NC.

Connector for control signals (I/O)

• GV series

Connector on amplifier side: Parts No. S10B-PASK-2 (J.S.TMfg.,Co.,Ltd.) or equivalent.

  mating connector: Representative Housing  PAP-10V-S, 

(

 Terminal  SPHD-001T-P0.5 or  SPHD-002T-P0.5            

)

Terminal 

number 

Terminal 

Symbol

Terminal name

Terminal explanation 

1

I

1

*1

Signal input 1

Operation instruction input 

*1

Motor runs when "

I

1" and "GND" are shorted, and stops when 

they are opened.

2

I

2

*1

Signal input 2

Rotation  changeover input 

*1

CW operation when "

I

2" and "GND" are shorted, and CCW 

operation when they are opened. 

*2

3

I

3

*1

Signal input 3

Free-run stop input 

*1

Free-run stop when  "

I

3" and "GND" are shorted,

4

I

4

*1

Signal input 4

Trip reset input 

*1

cancels a trip state when  "

I

4" and "GND" are shorted,

5

I

5

*1

Signal input 5

Free-run stop input 

*1

Free-run stop when  "

I

5" and "GND" are shorted,

6

GND

*3

signal ground

common ground of  analog speed input and input/output signal 

*3

7

FIN

For speed setting 

Input

Speed can be set by applying voltage DC0 to 5 V.

Input impedance 100 kΩ. 

8

+5 V

The power supply 

for external  

speed setting

Power output dedicated when connecting an external variable 

resistor (5 kΩ, B characteristics) to FIN input (Cannot be used for 

any other purpose.) 

9

01

※1

Signal output 1 

Trip signal output. 

*1

  "L" in trip (Contact ON)

Open collector Vce max: DC30 V, Ic max: 50 mA 

10

02

※1

Signal output 2

Velocity pulse output. 

*1

  (24 pulses / 1 rotation)

Open collector Vce max;   DC 30 V, Ic max;   50 mA 

*1  Function of input/output can be changed by the Digital key pad or panaterm for BL. Default is shown.

  Please refer to an operation manual (Overall) for details. 

*2 Rotation direction is that on motor shaft. When gear head is incorporated, the rotation direction of motor 

and that of gear output shaft are reversed for some gear reduction ratio. Please refer to the table of the 

permissible axis torque of “an operation manual(Overall ).” (CW: Rotation clockwise when see from the 

motor shaft, CCW: Rotation counterclockwise when see from the motor shaft)

*3 When resistor and control GND are disconnected in use of external variable resistor, 5 V is input to FIN 

irrespective of setting of variable resistor, and upper speed limit is directed; therefore use caution enough 

for connecting GND.

• the terminal number of the connector for control signals,pin No.1 is the SER connector side.

• When a control signal line is extended, please give as below 5 m. 

Summary of Contents for MINAS-BL GP series

Page 1: ...p this manual with care after reading and read as necessary Be sure to give this Instruction manual to an end user Label of safety precaution is affixed to the product If you are the first user of thi...

Page 2: ...rrent protection earth leakage breaker over temperature protecter and emergency stop device must be installed The failure could result in electric shocks injuries or fire Transportation wiring and che...

Page 3: ...d or not during transportation If any deficiency should be found contact the dealer store where you bought this product Checking the model of Amplifier Motor and Gear head This amplifier is designed f...

Page 4: ...reat influence upon the life of brushless amplifier therefore choose a place in conformance with the conditions below 1 Indoors where the motor is not subjected to rain water and direct sun beam 2 Do...

Page 5: ...ing to voltage specification When you use single phase connect the main power between L1 and L2 terminals 8 L2 10 L1 1 2 4 7 9 NC Do not connect anything to NC Connector for control signals I O GV ser...

Page 6: ...4 SIN 5 RS485 for connect RS485 6 RS485 for connest RS485 7 GND power supply GNG for Digital key pad 8 SCK Interface for digital key pad Maintenance inspections Routine maintenance and inspection are...

Page 7: ...is fact Brushless Amplifier Conformance to EC directive and UL standard Conformance to EC directive and UL standard Configuration of peripheral equipment Power supply 100 V system Single phase 100 V t...

Page 8: ...V P 1 Can be set by using the optional Digital key pad DV0P3510 sold separately or PANATERM for BL or through communication over RS485 2 The mark V is applied to the GV series P is applied to the GP s...

Page 9: ...an be downloaded from the following web site http industrial panasonic com ww i_e 25000 motor_fa_e motor_fa_e html Pursuant to at the directive 2004 108 EC article 9 2 Panasonic Testing Centre Panason...