EC Directives

The EC directives apply to all such electronic products as those having specific functions 

and directly sold to general consumers in EU countries.  These products are required to 

meet the EU unified standards and to be furnished with CE marking.

Our brushless motor meet the EC Directives for Low Voltage Equipment so that the 

machine or equipment comprising our AC servo can meet relevant EC Directives.

EMC Directives

Our brushless motor can meet EMC Directives and related standards.  However, to meet 

these requirements, the systems must be limited with respect to configuration and other 

aspects, e.g. the installation and some special wiring conditions must be met.  This means 

that in some cases machines and equipment comprising our servo systems may not satisfy 

the requirements for wiring and grounding conditions specified by the EMC Directives.  

Therefore, conformance to the EMC Directives (especially the requirements for emission 

noise and noise terminal voltage) should be examined based on the final products that 

include our system.

Applicable standard

Applicable standard

Installation 

condition

UL

UL508

 

Standard for electric converter equipment

Class I equipment

Pollution degree 2 

SCCR

 *1

CE

EN61800-5-1 

Adjustable speed electrical power drive systems. 

 

– Safety requirements. Electrical, thermal and energy

EN61800-3 

Adjustable speed electrical power drive systems.

 

– EMC requirements and specific test methods

EN55011 

Radio  interference  wave  characteristics  of  industrial,   

 

scientific,  and medical high-frequency equipment   

EN61000-6-2 

Standards for immunity in industrial environment

  

(EMC directive)

Overvoltage 

category II

Class I equipment

Pollution degree 2 

KC

Korea Radio Law 

*2

  Class A Instrument 

 

(commercial broadcast communications equipment)

*1  SCCR: Symmetrical current 5,000 Arms, Max. 240 V

 

Motor over-temperature protection is not provided. 

 

Motor over-load-temperature protection shall be provided at the final installation upon 

required by the NEC (National Electric Code).

*2  Information related to the Korea Radio Law

 

This brushless amplifier is a Class A commercial broadcasting radio wave generator 

not designed for home use. The user and dealer should be aware of this fact.

 

Brushless Amplifier

Conformance to EC directive and UL standard

Conformance to EC directive and UL standard

Configuration of peripheral equipment

Power 

supply

 100 V system: Single phase 100 V to 120 V ± 10%, 50/60 Hz

  200 V system: Single phase 200 V to 240 V ± 10%, 50/60 Hz

 Use the equipment under the environment of overvoltage category II specified by 

IEC60664-1.

 In order to obtain overvoltage category III, insert a transformer conforming to EN 

standard or IEC standard to the input of brushless motor.

 Use an electric wire size suitable to EN60204-1.

MCCB

(breaker)

Fuse

Be sure to connect a specified MCCB certified by IEC standard and UL, or a fuse 

certified by UL between power supply and noise filter. Observance of this condition 

allows conformance with UL508C (file No. E164620) .

Noise

 filter

When installing one noise filter at the power supply for more than one brushless 

motor used, contact the manufacturer of noise filter. 

Surge 

absorber

Install a surge absorber on the primary side of noise filter. However, in performing 

the voltage resistance test of machine and equipment, be sure to remove the surge 

absorber; otherwise, the surge absorber may be ruptured.

Grounding

Be sure to connect the grounding Terminal of brushless amplifier and protective 

grounding wire (PE) of system for preventing electric shock. Do not tighten the 

grounding wires together but connect them individually. 

Wiring of peripheral equipment

Molded Case

Circuit Breaker

(MCCB)

or Fuse

Brushless

amplifier

Brushless

motor

Surge 

absorber

Noise filter

Protection ground

(PE)

ground

Power

supply

Ferrite core (Noise filter for signal line)

option DV0P1460 (*Qty.

: 

4 ) (part No.: ZCAT3035-1330/TDK Corp.)

* The ferrite core should insert one 

  or more pieces in an electric wire, 

  respectively. 

List of compatible peripheral equipment

Part name

Optional part 

number 

(option)

Manufacturer's

part No.

Qty.

Manufacturer

Noise filter(single phase)

DV0P4170

SUP-EK5-ER-6

1

OKAYA ELECTRIC 

IND. CO., LTD.

Noise filter(3-phase)

DV0PM20042

3SUP-HU10-ER-6

1

Surge absorber(single phase)

DV0P4190

R

A

V-781BWZ-4

1

Surge absorber(3-phase)

DV0P1450

R

A

V-781BXZ-4

1

Noise filter for control signals

DV0P1460

ZCAT3035-1330

4

TDK Co.Ltd,.

Recommended circuit breaker

   Made by Sensata Technologies Japan Limited:

       Type IELH-1-11-63-5A-M (single phase)     Type IELH-1-111-63-5A-M (3-phase)

       (Rated current 5A, cutoff characteristics DELAY63)

       • Recommended cutoff characteristics: DELAY61-63

Summary of Contents for MINAS-BL GP series

Page 1: ...p this manual with care after reading and read as necessary Be sure to give this Instruction manual to an end user Label of safety precaution is affixed to the product If you are the first user of thi...

Page 2: ...rrent protection earth leakage breaker over temperature protecter and emergency stop device must be installed The failure could result in electric shocks injuries or fire Transportation wiring and che...

Page 3: ...d or not during transportation If any deficiency should be found contact the dealer store where you bought this product Checking the model of Amplifier Motor and Gear head This amplifier is designed f...

Page 4: ...reat influence upon the life of brushless amplifier therefore choose a place in conformance with the conditions below 1 Indoors where the motor is not subjected to rain water and direct sun beam 2 Do...

Page 5: ...ing to voltage specification When you use single phase connect the main power between L1 and L2 terminals 8 L2 10 L1 1 2 4 7 9 NC Do not connect anything to NC Connector for control signals I O GV ser...

Page 6: ...4 SIN 5 RS485 for connect RS485 6 RS485 for connest RS485 7 GND power supply GNG for Digital key pad 8 SCK Interface for digital key pad Maintenance inspections Routine maintenance and inspection are...

Page 7: ...is fact Brushless Amplifier Conformance to EC directive and UL standard Conformance to EC directive and UL standard Configuration of peripheral equipment Power supply 100 V system Single phase 100 V t...

Page 8: ...V P 1 Can be set by using the optional Digital key pad DV0P3510 sold separately or PANATERM for BL or through communication over RS485 2 The mark V is applied to the GV series P is applied to the GP s...

Page 9: ...an be downloaded from the following web site http industrial panasonic com ww i_e 25000 motor_fa_e motor_fa_e html Pursuant to at the directive 2004 108 EC article 9 2 Panasonic Testing Centre Panason...

Reviews: