93
-
-
92
-
Configuration of peripheral equipment
Power
supply
・
100 V system: Single phase 100 V to 120 V ± 10%, 50/60 Hz
200 V system: Single phase 200 V to 240 V ± 10%, 50/60 Hz
・
Use the equipment under the environment of overvoltage category II specified
by IEC60664-1.
・
In order to obtain overvoltage category III, insert a transformer conforming to
EN standard or IEC standard to the input of brushless motor.
・
Use an electric wire size suitable to EN60204-1.
MCCB
(breaker)
Fuse
Be sure to connect the specified Molded Case Circuit Breaker (MCCB) certified
by IEC and UL, or fuse certified by UL, between power supply and noise filter
so that symmetrical current upon short-circuiting of power source will not
exceed 5000 Arms. Meeting this condition allows conformance with UL508C (file
No. E164620) and UL1004 (file No. E166557).
Noise
filter
When installing one noise filter at the power supply for more than one
brushless motor used, contact the manufacturer of noise filter.
Surge
absorber
Install a surge absorber on the primary side of noise filter. However, in
performing the voltage resistance test of machine and equipment, be sure to
remove the surge absorber; otherwise, the surge absorber may be ruptured.
Grounding
Be sure to connect the grounding Terminal of brushless amplifier and protective
grounding wire (PE) of system for preventing electric shock. Do not tighten the
grounding wires together but connect them individually.
Wiring of peripheral equipment
Molded Case
Circuit Breaker
(MCCB)
or Fuse
Brushless
amplifier
Brushless
motor
Surge
absorber
Noise filter
Protection ground
(PE)
ground
Power
supply
Ferrite core (Noise filter for signal line)
option DV0P1460 (*Qty.
:
4 ) (part No.: ZCAT3035-1330/TDK Corp.)
* The ferrite core should insert one
or more pieces in an electric wire,
respectively.
Conformance to EC directive and UL standard
• DV0P4170
• DV0PM20042
Label
Terminal cover
(transparent)
2
−
ø
4.5
2
−
ø
4.5×6.75
53.1±1.0
100.0±2.0
88.0
75.0
5.0
12.0
10.0
50.0 60.0
7.0
2.0
(
11.6
)
(
13.0
)
6-M4
Label
115
105
95
5.5
10
43
70
52
Earth terminal
M4
M4
Screw
for cover
M3
Cover
Body
[Unit: mm]
List of compatible peripheral equipment
Part name
Optional parts
number (option)
Manufacturer's
parts number
Qty.
Manufacturer
Noise filter
(single phase 100, 200 V)
DV0P4170
SUP-EK5-ER-6
1
Okaya Electric
Industries Co. Ltd.
Noise filter
(3-phase)
DV0PM20042 3SUP-HU10-ER-6 1
Surge absorber
(single phase 100, 200 V)
DV0P4190
R
・
A
・
V-781BWZ-4 1
Surge absorber
(3-phase)
DV0P1450
R
・
A
・
V-781BXZ-4 1
Noise filter for control signals DV0P1460
ZCAT3035-1330 4
TDK Corporation
Noise filter