-
11
-
-
10
-
Installation
Environmental condition
Item
Condition
Ambient
temperature
Brushless motor
–10 ℃ to 40 ℃ (free from freezing)
*1
Brushless amplifier
0 ℃ to 50 ℃ (free from freezing)
*1
Digital key pad
(Option)
Ambient humidity
20% to 85% RH (free from condensation)
Storage temperature
At normal temperature and normal humidity
*2
Protection
structure
Brushless motor
IP65
(Excluding shaft pass-through section and lead wire connector)
•
This motor meets test requirements specified in EN
standards (EN60529 and EN60034-5). This motor
cannot be used for an application that requires long
term waterproof performance, such as the case where
the motor is always washed with water.
Brushless amplifier
Equivalent to IP20
Digital key pad
(Option)
Vibration
Not greater than 4.9 m/s
2
(10 to 60 Hz)
Altitude
Not greater than 1000 m
*1 Ambient temperature is measured at a distance of 5 cm from the product.
*2 Temperature which is acceptable for a short time, such as during transportation,
is –20 ℃ to 60 ℃ (free from freezing).
Installation of brushless motor
• Oil and water protection
(1) Direct down the lead of cable as far as possible.
(2) Avoid use in such an environment where the motor is always exposed to oil and water.
(3) Avoid use with cable immersed in oil or water.
• Stress to cable
(1) Make sure that stress is not applied to the lead or connection of cable due to bending
or dead weight.
(2) In installation where the motor moves, fix the cable of motor, and house the extension
cable connected to it in the cable bear to reduce stress by bending as small as
possible.
(3) Allow the bending radius of cable as large as possible.
Installation of brushless amplifier
The amplifier is a vertical placement type. Install it vertically and provide at least
10 cm space around it for ventilation.
(1) When installing with screw
Determine the fastening torque of the fixing screw
based on the strength of the screw and material of
the mounting surface, to ensure secure and safe
installation.
Example) To install to steel plate with steel screw (M4):
1.35 to 1.65 N
・
m
(2) When installing to DIN rail
The DIN rail mounting unit is available as option.
For details, refer to P.106.
Vertical
Location of
fixing screw
Location of
fixing screw
Cautions for Proper Use
(1) Because the control circuit is sensitive to temperature and impact, read this instruction
manual carefully for proper installation.
(2) The brushless amplifier switches the power element at a high speed to control the
motor. When the motor runs, leaking current will increase, which may activate the
leakage breaker. If this is the case, use a leakage breaker provided with measure
against high frequency for inverter.
Installation/ Caution