17
-
-
16
-
Wiring
Photo-coupler
Internal
power
supply
(+5 V)
I
1,
I
2,
I
3,
I
4
GND
GND
01, 02
Vce max DC30 V
Ic max 50 mA
1 kΩ
Input circuit
Output circuit
Connector for motor connection (MOTOR)
Connector on amplifier side: Parts No. 5569-08A1-210 (Molex Inc.) or equivalent.
(mating connector: Housing 5557-08R-210, Terminal 5556PBTL)
Terminal
number
Terminal
symbol
Terminal name
Terminal explanation
1
U
Motor U phase
Connect motor wire U, V and W.
2
V
Motor V phase
3
W
Motor W phase
4
5VS
High voltage 5 V
Not isolated from commercial power source.
Use care to avoid electric shock and
grounding fault.
5
CS1
CS signal 1
6
CS2
CS signal 2
7
CS3
CS signal 3
8
GNDS
High voltage GND
• High voltage is applied to motor wire and CS signal line; Use caution for avoiding electric shock.
• Use a motor extension cable (option) for extending motor wire.
• No.4 to 8 terminals of option cable are shielded, But the shield material is not grounded.
please do not ground the shield material in order to avoid malfunctions or damages.
Connector for communications (SER)
Modular jack: 85503-0001 (Molex Inc.) or equivalent
(RJ45)
Terminal
number
Terminal
symbol
Terminal explanation
• Connection of Digital key
pad of an option is possible.
Digital key pad connecting
cable of an option
(DV0P383**) is required.
• The terminal number of a
modular jack is the below
figure
1
—
Do not connect anything.
2
+5V
DC5 V power supply for Digital key pad
3
SOT
Interface for Digital key pad or
PANATERM for BL
4
SIN
5
RS485+
For connect RS485+
6
RS485−
For connest RS485–
7
GND
Power supply GNG for Digital key pad
8
SCK
Interface for Digital key pad
8
1
Connector for control signals (I/O)
Connector on amplifier side: Parts No. S10B-PASK-2 (J.S.TMfg.,Co.,Ltd.) or equivalent.
mating connector: Representative Housing PAP-10V-S,
(
Terminal SPHD-001T-P0.5 or SPHD-002T-P0.5
)
Terminal
number
Terminal
symbol
Terminal
name
Default
Terminal explanation
function
selection
logic
selection
1
I
1
*1
Signal
input 1 Run start
In turning on signal, short between
“
I
1” and “GND”.
*2
Pr50
Pr54
2
I
2
*1
Signal
input 2
Point
designation
In turning on signal, short between
“
I
2” and “GND”.
*2
Pr51
Pr55
3
I
3
*1
Signal
input 3
Home
sensor
In turning on signal, short between
“
I
3” and “GND”.
*2
Pr52
Pr56
4
(NC)
—
—
Do not connect anything.
—
—
5
I
4
*1
Signal
input 4 Forced trip
In turning on signal, short between
“
I
4” and “GND”.
*2
Pr53
Pr57
6
GND Control
ground
—
Common ground terminal for control
signal.
—
—
7
(NC)
—
—
Do not connect anything.
—
—
8
+5V Power
supply
—
Set 50 mA or below
—
—
9
01
※1
Signal
output 1 Trip output
Open collector output.
Open collector Vce max: DC30 V,
Ic max: 50 mA
Pr5C Pr5E
10
02
※1
Signal
output 2
In-motion
signal
Open collector output.
Open collector Vce max; DC 30 V,
Ic max; 50 mA
Pr5d
Pr5F
*1 Function of input/output can be changed by the Digital key pad or PANATERM for BL.
*2 Maximum rated voltage: –0.5 to 5.5V.
• Connector for control signals pin number is 1, 2, ... 10 in the order from grounding terminal side.
• Permissible length for control signal cable is 5m or less.