E13
-
-
E12
-
English
Wiring
Maintenance/inspections
02
Connector
for control
signals (I/O)
External speed setting
Variable resister 5 kΩ
B characteristic 1/4 W
Brushless
amplifier
change of
Direction
10
1
01
+
5V
FIN
GND
I
3
I
4
I
5
I
2
I
1
Power
supply
input
L1
L2
1
5
6
10
Be sure to ground the grounding terminal.
MCCB
Molded Case
(
Circuit Breaker
)
Grounding
Noise
filter
Brushless
amplifier
Power
supply
input
L1
L2
1
5
6
10
Be sure to ground the grounding terminal.
MCCB
Molded Case
(
Circuit Breaker
)
Grounding
Noise
filter
Run/Stop
command
GV series
Forced trip
02
Connector
for control
signals (I/O)
10
1
01
+
5V
(
NC
)
GND
I
3
(
NC
)
I
4
I
2
I
1
• In case of single-phase 100 V/200 V
GP series
Run start
Point designation
Home sensor
In wiring to power supply (outside of equipment) from MCCB, use an electric wire of 1.6 mm
diameter (2.0 mm
2
) or more both for main circuit and grounding.
Apply grounding class D (100 Ω or below) for grounding.
Do not tighten the ground wires together, but connect them individually.
Fastening torque of earth screws to be 0.49 to 0.98 N·m.
Routine maintenance and inspection are essential for proper and satisfactory
operation of the motor.
Notes to maintenance/inspection personnel
• Power-on/off operations should be done by the operators themselves for ensuring safety
in checking.
• Do not touch the motor while it is running or immediately after it stops because it gets hot
and stays hot for a while after power has been turned off.
• When testing the insulation resistance of the brushless amplifier with the megger,
disconnect the amplifier from all associated devices. Performing megger testing without
first disconnecting these devices will cause failure.
Maintenance/ Inspection item
Maintenance/
Check item
Inspection
procedure
Condition
Input voltage
Voltmeter Must be within ±10% of rating.
Input current
Ammeter
Must be within rated input current described on nameplate.
Insulation
resistance
Insulation
resistance
tester
The resistance of motor should be 1 MΩ or higher when tested
with a 500 V megger.
Brushless motor: Across phase (U, V, W) and ground terminals
Noise
Hearing
Noise level must not be different from the usual level. In
addition, abnormal noise such as rumbling noise must not be
heard.
Vibration
By hand
Free from abnormal vibration.
Grease
leakage
Visual check
Check that circumference of the motor and gear head are free
from oil and grease.
If grease leakage will cause problem, use grease sealing cover.
Installation
bolt
Torque
wrench
Check for loosening of bolt, and tighten additionally as
necessary.
Use
environment
By sight
Check the ambient temperature and humidity, and make sure
that dirt, dust, or foreign substance is not found.
When disassembly, troubleshooting, etc., is needed,
be sure to contact our service department or the sales agent of purchase.