34
11.2. Circulation Pump
The component is used for circulation of water inside the drum
in order to increase washing performance.
11.2.1. Technical Features
11.2.2. Checking of Component
Check the resistance value on the component with multimeter
as shown.
Resistance value should be between 160 - 180
Ω
.
Checking the component
11.2.3. Component Controlling By Con-
nection Measurement
You can determine the ohm value by measuring from the red
cable at 5th and red cable at 12th position in the small socket
(refer to 13 Wiring Connection Diagram) as shown in belows
figures.
Resistance value should be between 160 - 180
Ω
.
Nominal voltage
220 - 240 V
Frequency
50 Hz
Resistor (coil)
169,5
Ω
(±5 %)
Summary of Contents for NA-A47VB4WDE
Page 3: ...3 1 Safety Precautions ...
Page 6: ...6 4 Location of Controls and Components ...
Page 13: ...13 ...
Page 43: ...43 12 Dimensions ...