7 Disassembly and Assembly Instructions
7.1.
Magnetron (Upper and Lower)
Upper magnetron
1. Discharge electric charge remaining on the high voltage
capacitors.
2. Remove the entire rear panel by removing screws as
shown.
3. Disconnect all lead wires from magnetron and thermal
cutout.
4. Remove the 4 screws holding magnetron.
5. Remove 2 screws holding thermal cutout.
6. Remove the mounting bracket from magnetron and install
it on the new magnetron.
Lower magnetron
1. Discharge electric charge remaining on the high voltage
capacitors.
2. Remove the entire rear panel by removing screws as
shown.
3. Carefully place the unit on its left side (H. V. Capacitor
side).
4. Remove the cover by removing 2 screws.
5. Remove the 4 screws holding magnetron by inserting
screwdriver through the 4 openings on bottom plate.
6. Remove 2 screws holding thermal cutout.
7. Remove the mounting bracket from magnetron and install
it on the new magnetron.
NOTE: To prevent microwave leakage, tighten mounting
screws diagonally and properly making sure there is no
gap between the waveguide and the magnetron.
Summary of Contents for NE-2153-2EYG
Page 3: ...3 3 Location of Controls and Components 3 1 Outline diagram...
Page 4: ...4...
Page 5: ...5 4 Operating Instructions 4 1 Operation procedure...
Page 6: ...6...
Page 7: ...7...
Page 8: ...8...
Page 9: ...9...
Page 10: ...10...
Page 11: ...11...
Page 12: ...12...
Page 13: ...13...
Page 14: ...14...
Page 15: ...15...
Page 16: ...16...
Page 17: ...17...
Page 22: ...22 6 2 Troubleshooting guide...
Page 28: ...28 9 Wiring Connection Diagram NOTE When replacing check the lead wire colour as shown...