3. Turn over the power base, place it horizontally on a stable
surface and make sure that the power base is placed stably.
Then rotate the bottom knob counterclockwise to remove
the knob.
Note: Scalds may be caused. Make sure the product is
completely cooled before opening.
The knob shall not be opened during use.
4. Turn over the power base and shake it horizontally several
times to pour out the scale and impurities in the boiler inside
the product.
5. Add an appropriate amount of water to the drainage outlet
on the bottom of the power base and shake the power base
horizontally several times.
6. Turn over the power base, and pour out the scale and
impurities in the main body.
7. Repeat steps 4-5.
Repeat the cleaning process until all the scale and
impurities in the main body are poured out. This can prevent
reduction of the amount of steam caused by increase of
scale.
Drainage outlet
19
18
8. After pouring out all the scale and impurities, tighten the
knob, restart the product and press the “RESET” button.
Then the product can work properly.
Sealing
rubber ring
Note: Before tightening the
knob, make sure that
the sealing rubber ring
cannot be dislodged.
9. Wind and place the corded hose and power cord in the
cable trough and store the product in a safe place.
Storage of the
corded hose
Storage of the power cord
•
Cleaning frequency:
After the descaling indicator lights up.
Note:
Depending on the using region and water quality, the
product may need to be descaled multiple times.
Notes:
•
Steam output may be significantly decreased before
the descaling indicator turns on, depending on the
using region or the composition of the used tap water.
Therefore, cleaning is recommended before the
descaling indicator turns on.
•
If steam output is significantly decreased after
cleaning, the scale inhibitor may be used up soon.
Please contact the after-sales service personnel for
replacement of parts.
•
In addition to the reduced effect of the descaling agent,
the shortened service life of the product may also result
in decreased steam output.
•
When the product will not be in use for a long period of
time:
•
For
NI-GT200
only: Drain water in the water tank and
rotate the temperature selector to set the product to the
“Silk” steam level.
•
For
NI-GT500
only: Drain water in the water tank and
press the level adjustment button to set the product to the
optimal care steam level.
Specifications
Model
NI-GT500
NI-GT200
Rated voltage
220-240 V
50-60 Hz
Power consumption
2 000-2 400 W
Weight
Approx. 4.4 k
g
Approx. 4.3 k
g
Dimensions
(assembly)
(W x D x H)
Approx. 350 × 200 × 300 mm
Power plug/Cord
length
Single-phase 3-pole plug/
Approx. 1.8 m
Water tank capacity
Approx. 1.8 L
This product is intended for household use only.