a) Lift the Indicator light assembly from the Heat-insulated
plate. Remove the screws indicated by arrows and
lift the Heat-insulated plate.
b) Lift the Packing(c). (NI-JW670C/JW660T only)
1.
INSTALLAT
ION OF HEAT‑INSULATED PLATE
(ATTACH THE HANDLE)
Before installing the Heat-insulated plate, ought to turn
the Temperature selector dial in a clockwise direction
to the end of position.
7.
REMOVAL OF HEAT‑INSULATED PLATE
Remove the Fixed plate screws by arrows and lift the
Auto-valve assembly, then remove the Disc bimetal.
8.
REMOVAL OF AUTO‑VALVE ASSEMBLY
DIRECTIONS FOR REASSEMBLY
(REASSEMBLY
IN THE ORDER REVERSES
FOR THAT OF DISASSEMBLY.)
2.
INSTALLAT
ION OF TEMPERATURE
SELECTOR DIAL
Before installing the Temperature selector dial,ought to
turn the Temperature selector dial to maximum temperature
position then install it into Water tank.
Temperature adjustor
Heat-insulated plate
Indicator
light
Packing(C)
Auto-valve assembly
Soleplate
Thermostat stopper
Soleplate
Temperature selector dial
Turn the Temperature
selector dial to maximum
temperature position
Temperature dial
supporter
―
5
―