TEMPERATURE TEST METHOD
(CONF
IRM WI
TH AN OHMMETER)
1. Fill the iron as described in
" HOW TO FILL
WI
TH WATER "
in the
Operating Instructions
.
2. Set the iron vertically and make sure the Temperature selector dial is set to " 0 " (or " Off " ).
Plug the AC cord into the electrical outlet.
3. Set the Temperature selector dial to the steam zone
4. Preheat the iron until the Indicator light goes out, usually in about
1-2 minute.
5. Hold the iron horizontally and move the Steam/Dry selector into the steam
position. Now steam ironing can begin.
6. Anytime the iron is set vertically the steaming action will stop.
Step1.
Step2.
Step3.
Step4.
Step5.
To cool, unplug and allow the
iron to room temperature.
Attach the ohmmeter leads
across both plug prongs.
Adjust the temperature selector dial
to the "0" position..
Meter should indicate open
condition.
Temperature selector
Point to adjust dial
If the meter needle deflects while
the temperature selector dial is
within the range shown by arrows
(A) and (B) then iron is working
normal.
If the temperature selector dial causes the meter to deflect before point
(A) , turn the adjusting screw clockwise 1/4 turn then go back to Step3.
If the temperature selector dial causes the meter to deflect beyond
point (B) , turn the adjusting screw counterclockwise 1/4 turn then
proceed Step3.
NOTE: While adjusting for the proper setting it may be necessary
to repeat Step 4 several times.
STEAM TEST
Scale position
Dial thermo
Meter
AC Power
cord plug
Contact
adjustor
Adjusting screw
(Angle direction)
―
7
―