English
- Eng-31 -
Sensor Reheat Setting
Considering IR sensor positioned on the upper head of the side wall, if it fails to detect the surface temperature of the foods
or liquids themselves, in that way the detected temperature will be different from the actual temperature. Therefore, we do
not recommend using straight-sided containers with narrow necks when reheating small amount of food or liquids, in that the
side wall of the container will obstruct the infrared rays to get through and lead to error detection. In order to achieve best
performance, the following steps should be taken:
1. When reheating solid foods, please use open,
fl
at container with food weight no less than 100
g
.
2. When reheating liquids, avoid using straight-sided containers with narrow necks, and liquids under 200 ml.
IR sensor detects
the food temperature
rightly.
IR sensor may fails
to detect the food
temperature, in that the
side wall of the container
obstruct the infrared ray
given out by the food.
3. The default setting is 70 °C when plugging in. From the second time, the default setting will be changed to previously
setting if between 55~75 °C.
4. "
" will be displayed if food temperature measured is higher than selected temperature.
5. After reheating, stir then serve.
6. Please place the container at the Centre of the
fl
at table.
7. The plastic wrap should cover the food tightly, otherwise, the temperature of food may not be tested. If the plastic wrap is
overlapped, make sure the overlapped area is placed downwards.
Plastic
fi
lm
Food
8. Food less than 100
g
can not be detected. It may cause overcook.
9. If the temperature of the cavity is too high, sensor reheat feature can not be used. Display window will appear "
".
Sensor reheat feature can be used again until the "
" disappear.
10. The actual temperature maybe different from the required temperature. It depends on the cavity temperature, the food
density, the container, the placement of the food etc.
11. Avoid using straight-sided containers with narrow necks when using Sensor Reheat.
1. Press once.
"
"
symbol and
"1"
will appear in the
display.
3. Press once. The temperature you set will
display. After detecting for a period of time,
press
Reheat
pad and the approximate
current temperature will appear in the
display window for 3 seconds.
(unnecessary step)
Sensor Reheat feature is utilizing the IR sensor equipped within the cavity to detect surface temperature of the food in the MWO
to balance the reheating temperature and timing. This feature can cook food without setting power and time, only according to
the temperature as your require. The
fi
eld is -10~90°C. The recommended weight is 100-500
g
.
2. Set the required temperature by
using the dial.