3.4 When the 8 Amp fuse is blown due to the
operation of short switch:
WARNING
When the 15 Amp fuse is blown due to the operation of short switch, you must replace Primary latch switch and short switch. Also replace power relay B (RY1) when the
continuity check reads shorted contacts(12).
1. This is mandatory. Refer to “Adjustments and Measurement” for these switches.
2. When replacing the fuse, confirm that it has the appropriate rating for these models.
3. When replacing faulty switches, be sure mounting tabs are not bent, broken or otherwise deficient in their
ability to hold the switches.