XII. SAFETY CHECK
Make sure that the refrigerator repaired is secure and works properly.
1. INSULATION TEST
1
2
3
4 Switch on the power of insulation tester.
( Standard: 500 V/ DC, > 10 Ohm ).
2. PUNCTURE TEST
1
2
3
4
5
6
Connect the Service Cord Puncture test into Elctric
source.
Setting Puncture Test at 1500VAC, 5 mA,
1 minute.
Connect the high voltage cord's pin to the cabinet
and switch on puncture test.
Connect the Service Cord pin to each
other.
Connect the grounding pin and insulation
tester to service cord of Refrigerator.
Connect positif pin Insulation tester to
body of Refrigerating Unit.
Connect the Service Cord to each other.
Place the refrigerator on the wooden surface.
Connect the pin of ground puncture test to the
Service cord of Refrigerator.
Insulation test
Puncture test
-18-