X. REFRIGERATING UNIT REPAIRING PROCEDURE
STANDARD PROCEDURE
Diagnosing the trouble
Discharging the refrigerant
Removing the Compressor
Checking the compressor oil
A little discoloration
(light yellow)
Severe discoloration
(light brown)
Purging the pipe at
high-pressure side
Purging the pipe at low-
pressure side
Setting the compressor and the dryer
Vacuum pumping and pot the electric parts
Charging the refrigerant
Leakage test
Test Run
Pinch-off seal of charge pipes
Finish
IMPORTANT POINTS
Refer to the TROUBLE SHOOTING
* For purging the pipe, use HFC-134a as liquid state.
* Never use HCFC-141b, HCFC-22 for purging.
* Do not keep the pipes open to air more than 30
minutes.
These process in total should be finished within 30
minutes.
* Rubber caps should be removed just before
compressor is used. Never leave the compressor
without the caps and open to the air.
Be sure to connect the adaptor with vacuum pump.
Charge cylinder should be exclusive - use for HFC-
134a.
This is to prevent different refrigerant (CFC-12,
HCFC-22, CFC-113, HFCFC-141b, R-502) from
mixing with HFC-134a.