Evap pan (Backside of the refrigerator)
Troubleshooting
The refrigerator
does not operate.
●Check that the plug and its socket are in good condition.
●Check if there is any problem on main fuse and electrical system of the
house.
●Check by unplug and wait for 10 minutes before plugging it back in.
The refrigerator
does not cool
enough.
●Check to be sure that light in control panel is displayed at proper
position.
●Check to see if the refrigerator is overloaded with stuff or there is any
hot foodstuff refrigerated inside.
●Is the refrigerator exposed directly to sunlight or heat source?
●Is the refrigerator door completely closed?
●Is the refrigerator door opened frequently?
Vapor generated
inside and outside
the cabinet / surface
of door.
●Condensation may appear on the surface of cabinet when humidity is
high, e.g. during rainy season or the air circulation is not good.
●If there is condensation inside, check if the door is completely closed.
Is the refrigerator frequently opened or left open for a long time?
Is there any hot foodstuff refrigerated inside?
The refrigerator
generates noise.
●Check if the refrigerator is located on a stable fl oor or is installed properly.
●Check if there is any object in contact with the refrigerator.
●After installation, the refrigerator may make loud noise. The noise
become small when the refrigerator has been cooled.
Food becomes
frozen
●Do you put the food near cold air duct?
●Do you adjust the temperature control at “Max”? Adjust to “Min”.
●Do you put food in chill case?
Removing
1
. Tilt up the evap pan
a bit and then lift it
upward until the evap
pan hole unlocks from
the hook evap pan.
2
. Pull the evap pan
until it touches with
the evap pipe then
carefully take it out
under the evap pipe.
Requests
●
Do not damage or deform the evap pipe.
Attaching
1
. Insert the evap pan under the evap pipe.
2
. Insert the evap pan hole into the hook evap
pan as well as press-fi tting both sides.
2
Evap pipe
1
1
2
2
Evap pipe
Hook evap pan
11