NR-BY558/NR-BY55B/NR-BY608
6. SELF DIAGNOSING FUNCTION
When abnormal is cased in the refrigeator, the sign is displayed on LED as below chart
How to use “ Self diagnosing “ function ( Door control model )
1. Opening PC door push “ Fridge button “ more then 5 sec.
2. After blinking sec., each LED show as below.
3. “ Self diagnosing “ function will be automatically cancel after 7 min., from start operation.
How to use “ Self diagnosing “ function ( Door control model )
1. Opening PC door and Door switch depressed push “ Fridge button “ more then 5 sec
( Initially , all LED will be on for 3 sec )
2. After blinking at see, each LED show as below.
3. “ Self diagnosing “ function will be automatically cancel after 7 min., from start operation.
Display
Priority
Error mode
Correspondent code
(diagnostic code can be displayed)
QF
LED
Dial Control LED
Min.
Mid.
Max.
HC refrigerant leak (low pressure leak)
H36
●
●
HC refrigerant leak (high pressure leak)
H35
ATC thermistor break/short
H07 (abnormal ATC)
●
DFC thermistor break/short
H05 (abnormal DFC)
●
FCC thermistor break/short
H01 (abnormal FCC)
●
PCC thermistor break/short
H02 (abnormal PCC)
●
●
PFC thermistor break/short
H03 (abnormal PFC)
●
●
Abnormality of FC heater
H31 (abnormal ATC FC heater)
●
Inverter compressor is abnormal
H40 (Over current protection, lock protection)
●
●
●
H41(Low voltage protection)
H52(Abnormal over voltage protection)
Control PCB is abnormal
H50 (Abnormal communication)
●
H51 (Abnormal EEPROM)
illumination senser break/short
H64
●
●
●
Normal
Normal
●
●
●
●
: off
●
: light :
fl
ash (0.16s ON / 0.16s OFF)
- 11 -