23
4. If the sign "H**"is displayed on LED, press "Refrigerator" button for 5 seconds.
H**sign will disappear on LED soon.
If the defective condition continues, the "H**"sign will be displayed again.
("U10"and defective record will not be deleted.)
5. "U10"will disappear when to unplug. However trouble continue, the sign "U10"appear again.
6. When some troubles happens on same time, LED indicates each sign for 1 second.
7. *2...If a signal circuit is disconnected, a fan motor will become a high velocity revolution and a refrigerator will not cause the
shortage of cooling.
8. *3..All LED on the door blinks at the same time when "H43" displays.
9. It becomes a protection stop, about eight days after H21 display, and the test control doesn't work.
Detaching the power plug or the connector detaching in ice maker A’ssy lead line is necessary for the restart of the control.
Summary of Contents for NR-F532TT
Page 8: ...8 3 General Introduction 3 1 Flow of Refrigerant 3 2 Flow of cold air inside compartments ...
Page 9: ...9 3 3 Flow of cold air duct ...
Page 10: ...10 4 Features 4 1 Self cleaning of the whole compartment ...
Page 18: ...18 6 Location of Controls and Components 6 1 Components ...
Page 19: ...19 6 2 Control panel and Control button ...
Page 24: ...24 11 Troubleshooting Guide 11 1 Not cooling at all Compressor does not run ...
Page 28: ...28 11 5 Ice cubes can not be made FC cooling condition is normal ...
Page 45: ...45 13 Maintenance 13 1 KNACK FOR MAINTENANCE ...
Page 46: ...46 13 2 MAINTENANCE OF ICE MAKER ...
Page 47: ...47 14 Dimensions 14 1 OUTSIDE ...
Page 48: ...48 14 2 INSIDE ...
Page 49: ...49 14 3 BOTTOM ...
Page 50: ...50 15 Wiring Connection Diagram 15 1 SCHEMATIC DIAGRAM ...
Page 51: ...51 16 Exploded View and Replacement Parts List 16 1 EXPLODED VIEW 1 ...
Page 54: ...54 16 3 EXPLODED VIEW 2 ...
Page 56: ...56 16 5 EXPLODED VIEW 3 ...
Page 58: ...58 16 7 EXPLODED 16 8 VIEW 4 ...
Page 60: ...60 16 10 EXPLODED VIEW 5 ...