9.3.3. PREPARATION
1. Insert a flat headed (-) screwdriver or similar object, remove
the EVR Cover.
2. Connect the Connection Adaptor and the 2 EVR Connector
Boards. Then, connect the 30 pin Flat Cables to P101 and
P102 on the Interface Board.
Fig. E1-1
Note:
When connecting them, pay attention to the direction of
them.
3. Connect them to the Connector B2 on the Main C.B.A.
Fig. E1-2
4. Connect the AC Adaptor to the camcorder.
5. Connect the DC Output Cable (and AC Adaptor) to the J101
on the Measuring Board.
6. Connect the J102 on the Measuring Board to RS232C of
the PC with 232C (M3) I/F Cable.
7. Set the SW101 (RS232C_SEL) on the Measuring Board to
"M3."
8. Set the SW102 (FLUSH1) on the Measuring Board to
"NORMAL."
9. Set the SW103 (VTR_TEST) on the Measuring Board to
"NORMAL."
10. Set the SW104 (BST_TEST) on the Measuring Board to
"NORMAL."
11. Set the SW105 on the Measuring Board to "L."
12. Set the SW106 on the Measuring Board to "ON."
13. Set the SW107 on the Measuring Board to center.
14. Set the SW108 on the Measuring Board to "L."
15. Set the SW109 (FLUSH2) on the Measuring Board to
"FLUSH."
16. Power on the set.
62
NV-GS6EE / NV-GS6GC / NV-GS17E / NV-GS17EB / NV-GS17EF / NV-GS17EG / NV-GS17EP / NV-GS18E / NV-GS21E / NV-GS21EB / NV-GS21EG / NV-GS21EK / NV-GS21EP / NV-GS25GC / NV-GS25GN /
GS28GK / NV-GS35E / NV-GS35EB / NV-GS35EG / NV-GS35EP / NV-GS35GC / NV-GS35GN / NV-GS38GK