38
Indica
tion
Condition of the Detection
Movement of the Mechanism
Remedy
/Check
Automatic
Indication
H18
T-reel lock detection in constant running of the T-reel.
If the T-reel pulses could not be detected over the regulated time while
tape is running, it is judged T-reel lock.
l
“18” is memorized on the self- diagnosis history.
l
The mechanism is shifted to LOAD position and tape rewinding is
performed.
l
The mechanism is shifted to PLAY position, and then stopped.
l
The self-diagnosis history is not remained when an Error in FF or REW,
the mechanism is shifted to LOAD position, and then rewinding is
performed.
l
The mechanism is shifted to PLAY position, and then the pinch pressure
runs the tape.
l
If an Error is detected again, “18” is memorized on the self-diagnosis
history.
l
The mechanism is shifted to LOAD position, and then tape rewinding is
performed.
The mechanism is shifted to PLAY position, and then stops.
Please check
mechanism T-reel
system, T-reel
sensor, T-reel
sensor input signal
circuit, Capstan
motor, Capstan
motor drive circuit,
Capstan control
signal circuit, and so
on.
Yes
H80
Exceptional EJECT
l
If the S-reel pulse is less than 3 pulses between LOAD position
and PLAY position when the loading is finished, it is judged miss
catching the tape.
l
If the rewinding has not finished within the regulated time when
the short rewinding on DOWN position, It is judged that the tape
could not be rewound.
l
If the mechanism lock is occurred during the loading to LOAD
position, it is judged that the loading could not be performed.
l
If the both ends are detected at LOAD position, it is judged that the
tape is cut off.
l
EJECT is performed.
l
“80” is memorized on the self-diagnosis history
l
Reason of the ejection is memorized on the “supplementary data 2”.
No
F2*
Error while the PG Automatic Adjustment
Yes
WHAT ARE THE DIFFERENCES BETWEEN Z-MECHANISM & R4-MECHANISM, IN TERMS OF SELF-DIAGONOSIS MODE?
1.
OPERATION AFTER DETECTING THE ERROR:
The Mechanism operation, after detecting the error has been changed.
2.ADDITION OF ERROR NUMBER [H 80].
In very rare cases, although VCR works fine, it might be detected as malfunction.
In such a case, the error code has just memorised in history of self-diagnosis result without displaying it on FIP, to prevent needless afraid of user.
However, its data can be displayed as the supplementary data 2, to clarify the course of Ejection. (Refer to the supplementary data.)
3.DETECTING METHODS of [F15] HAS BEEN CHANGED:
In Z-Mechanism, the error code; [F15] has been detected using S-Reel pulse, it means that
the [F15] shows “S-Reel pulse does not existed although cassette is inserted.”
However, in R4-Mechanism, the error code; [F15] has been detected using Capstan FG pulse, it means that the [F15] shows “Capstan FG pulse does not existed although cassette is inserted.”
(The reason of this modification is that impossibility of checking the S-Reel pulse due to Mechanism construction change.
Summary of Contents for NV-HV61GN
Page 21: ...2 REMOVAL OF THE BACK PANEL Remove 2 Screws C Remove Screw D Unlock 4 Tabs E Fig D3 21 ...
Page 29: ...10 2 CASING PARTS SECTION 29 ...
Page 30: ...10 3 PACKING PARTS SECTION 30 ...
Page 31: ...11 REPLACEMENT PARTS LIST 31 ...
Page 41: ...C4537 ECJ2VC1H560G CHIP CAPACITOR 41 ...
Page 44: ...D2002 B0AAED000003 DIODE 44 ...
Page 47: ...Q1152 2SC3311ASA TRANSISTOR 47 ...
Page 49: ...R1502 ERJ3GEYJ273V CHIP RESISTOR 49 ...
Page 54: ...W519 ERJ3GEY0R00V CHIP JUMPER 54 ...
Page 109: ...4 1 3 PARTS NAME OF R4 MECHANISM Fig M2 ...
Page 139: ...34 ...