10.8.1. DISASSEMBLING THE OPTICAL PICKUP UNIT
1. Remove the two screws and remove the TRV feed rack.
2. Remove the FFC cable.
3. Remove the optical pickup.
Fig. 1
10.8.2. CAUTIONS TO BE TAKEN WHEN REPLACING THE OPTICAL PICKUP
- Replace the optical pickup according to the following procedure.
1. Install the TRV feed rack on the optical pickup (see
Fig. 1
).
2. Install the Optical Pickup Unit, Spring, Drive shaft, Guide shaft
and Spring holder on the Traverse block.
Cautions to be taken when assembling the unit: Install the Pickup
Unit so that it is located at the rear end of the Guide shaft.
3. Install the FFCable (see
Fig. 1
).
Fig. 2